3-2
Sun StorEdge T3 Disk Tray Installation, Operation, and Service Manual • July 2000
1. Ensure that the data path between the host and the disk tray has been quiesced.
There must not be any I/O activity.
2. In a telnet session with the disk tray, type:
3. Press the power button once on each power and cooling unit to turn the switch off
(
).
FIGURE 3-1
Power Switch Locations
3.1.2
Powering On
When powering on a configuration, always power on the Sun StorEdge T3 disk trays
before booting the host server.
●
Power on the master unit by pressing the power button on each power and
cooling unit.
At this point, all power and cooling unit LEDs on the disk tray and any units
connected to it will turn green, indicating that power has been restored.
Note –
If the green power and cooling unit LEDs on connected units do not light,
then press the power switches on those units.
t300:/:<1>shutdown
Shutdown the system, are you sure? [N]: y
Power switches
Summary of Contents for Sun StorEdge T3
Page 6: ...vi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 14: ...xiv Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 26: ...xxvi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 38: ...1 12 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 84: ...2 46 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 104: ...4 10 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 134: ...A 6 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...