2-38
Sun StorEdge T3 Disk Tray Installation, Operation, and Service Manual • July 2000
4. Use the
vol add
command to create the default volume on the alternate master as
follows:
a. Define the volume name (
vol add v1
).
b. Define the drives on which the volume will reside (
data u2d1-9
).
c. Define the RAID level (
raid 5
).
■
v1
is the volume name
■
u2d1-9
indicates the location of the volume: unit 2, disk drives 1 through 9
■
raid 5
is RAID level 5
5. Type
vol stat
to check the status of the volumes.
The status of all drives must be
0
. For example:
6. Use the
vol init
command to initialize the volume on the alternate master.
Depending on system activity at the time of initialization, it can take up to an hour
to initialize a volume. Only one volume can be initialized at a time
7. Use the
vol mount
command to mount the volume on the alternate master.
t300:/:<4>vol add v1 data u2d1-9 raid 5
t300:/:<5>vol stat
v0 u1d1 u1d2 u1d3 u1d4 u1d5 u1d6 u1d7 u1d8 u1d9
mounted 0 0 0 0 0 0 0 0 0
v1 u2d1 u2d2 u2d3 u2d4 u2d5 u2d6 u2d7 u2d8 u2d9
unmounted 0 0 0 0 0 0 0 0 0
t300:/:<6>vol init v1 data
t300:/:<7>vol mount v1
Summary of Contents for Sun StorEdge T3
Page 6: ...vi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 14: ...xiv Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 26: ...xxvi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 38: ...1 12 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 84: ...2 46 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 104: ...4 10 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 134: ...A 6 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...