Chapter 5
Service
5-23
To upgrade the disk drive firmware:
1. Start an FTP session from the management host to the disk tray.
For example:
2. Log in to the disk tray by typing
root
and the root password at the prompts.
3. Type
binary
to set the transfer mode.
4. Copy the firmware file from the working directory on the host to the
/
directory on
the disk tray.
5. Type
quit
to exit the
ftp
session.
mngt_host:/:<15>ftp 129.150.47.101
Connected to 129.150.47.101.
Escape character is ’^]’.
220 129.150.47.101 pSOSystem (NUPPC/2.0.0-G) ready
Name (129.146.81.201:root):
Name (129.146.81.201:root): root
331 Password required for root.
Password:
password
230 User root logged in.
ftp>
ftp> binary
ftp> put
firmware
200 PORT command successful.
150 Binary data connection for
filename
(129.150.47.101,1031).
226 Binary Transfer complete.
162 bytes received in 1 seconds (0 Kbytes/s)
ftp>
ftp>
quit
221 Goodbye.
mngt_host:/:
Summary of Contents for Sun StorEdge T3
Page 6: ...vi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 14: ...xiv Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 26: ...xxvi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 38: ...1 12 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 84: ...2 46 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 104: ...4 10 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 134: ...A 6 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...