2-10
Sun Fire X4140 Server Service Manual • September 2010
2.8
Removing the Top Cover
The top cover and fan door are integrated.
Note –
Some field-replaceable units (FRUs) require removal of the top cover.
1. Unlatch the fan module door. (
FIGURE 2-6
) [1]
Pull the two release tabs back to release the door. Rotate the fan door to the open
position and hold it there.
2. Press the top cover release button and slide the top cover toward the rear of the
server, about a half-inch (12.7 mm). [2]
3. Lift up and remove the top cover. [3]
Caution –
If the top cover is removed before the server is powered off, the server
will immediately go into Standby mode.
FIGURE 2-6
Removing the Sun Fire X4140 Server Top Cover
Summary of Contents for Sun Fire X4140
Page 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Page 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Page 35: ...Chapter 2 Preparing to Service the System 2 11...
Page 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Page 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Page 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Page 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...