5-24
Sun Fire X4140 Server Service Manual • September 2010
c. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-5
.
d. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-5
.
5.8.5
Removing a PDB Cable
To remove a Power Distribution Board cable.
1. Prepare the server for service.
a. Power off the server.
See
Section 2.4, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.4, “Powering Off the Server” on page 2-4
.
c. Slide the server out of the rack.
See
Section 2.5, “Extending the Server to the Maintenance Position” on
page 2-5
.
d. Attach an antistatic wrist strap.
See
Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
e. Remove the top cover.
See
Section 2.8, “Removing the Top Cover” on page 2-11
.
2. Remove the PDB end of the cable.
a. Release the latches on either side and then pull the cable straight up.
b. Grasp each end of the connector on the motherboard, and then pull straight
up to disconnect from connector.
Caution –
Do not to bend the pins on the unshrouded motherboard connector.
Summary of Contents for Sun Fire X4140
Page 1: ...Sun Fire X4140 Server Service Manual Part No 820 2401 14 September 2010 Revision A...
Page 24: ...1 12 Sun Fire X4140 Server Service Manual September 2010...
Page 35: ...Chapter 2 Preparing to Service the System 2 11...
Page 36: ...2 12 Sun Fire X4140 Server Service Manual September 2010...
Page 94: ...4 40 Sun Fire X4140 Server Service Manual September 2010...
Page 126: ...6 6 Sun Fire X4140 Server Service Manual September 2010 FIGURE 6 5 Front Panel Power OK LED...
Page 140: ...C 4 Sun Fire X4140 Server Service Manual September 2010 FIGURE C 1 BIOS Utility Menu Tree...