36
Sun StorEdge N8400 Filer Installation, Configuration, and Service Guide • August 2001
Note –
In some cases, if a disk drive is removed and replaced on a powered-off or
incompletely booted array, the internal system monitoring facilities may not
correctly detect the drive replacement. Therefore, always replace disk drives on
powered-on, fully booted arrays only.
For more information refer to:
■
Sun StorEdge T3 Array Installation, Operations, and Service Manual
■
Sun StorEdge T3 Array Administrator’s Guide
▼
To Verify Drive Reconstruction
To check the status of a drive and verify the reconstruction of the data, choose one of
the two following methods:
■
Visual. When you place the new drive into the array, the following sequence
should take place:
■
Disk drive amber LED blinks fast. Disk is spinning up.
■
Disk drive green and amber LEDs blink fast. Disk is being initialized.
■
Disk drive green LED blinks fast and amber LED is steady. Disk is being
reconstructed.
■
Disk drive green LED is steady. Done.
■
Telnet. Start a telnet session to the array and use the
proc list
command via
the array’s command-line interface (CLI).
Note –
Do not confuse the array CLI with the filer CLI. The filer CLI is used to
access a simplified set of commands to manage the system.
An output similar to the following should be displayed.
t300:/:<35> proc list
VOLUME
CMD_REF
PERCENT
TIME
COMMAND
v1
20241
23
0.09
vol recon