Depending on the array’s configuration, one or two ESMs monitor and report the
status of the disk drives.
FIGURE 1-6
Disks Controlled by a Single ESM and by Two ESMs
In a
single-bus
configuration, as indicated on the left in
, the single ESM
controls all disks. In a
split-bus
configuration, the array becomes two independent
storage subsystems. Each ESM monitors half the disks (all disks in the six drive slots
that are diagonally across from it).
Unit ID
Ten-position switch for setting a unique ID for each ESM. When this switch is
used to set a unit ID, an application (such as Network Storage Agent) can use
SAF-TE commands to locate the ESM by its ID. See
for a close-up.
ESM Over
Temperature/Code
Download LED
Yellow: Temperature exceeds the factory preset limits. When this LED is yellow,
the Subsystem LED also turns amber. (See “Array Front With Door Open and
Disk Slots Accessible” on page 1-7 for the location of the Subsystem LED.)
Blinking: A code download is in progress.
Off: Temperature is normal, and a code-download is not in progress.
Power ON/SCSI
Active LED
Green: Power is applied.
Blinking: SCSI activity is occurring through the ESM.
Off: Controller is not receiving power.
TABLE 1-5
Connectors, Switches, and LEDs on the ESM
ESM 0
ESM 0
ESM 1
Front
Back
Single-bus configuration
Split-bus configuration
Summary of Contents for StorEdge D2
Page 10: ...x Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 50: ...2 12 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 92: ...4 28 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 98: ...B 2 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 104: ...B 8 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 114: ...B 18 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 118: ...Index 4 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...