Detecting and Managing Faults
27
set /HOST/bootmode
property
=
value
[where
property
is
state
,
config
,
or
script
]
bootmode [normal] [reset_nvram]
[config=
configname
] [bootscript=
string
]
Controls the host server OpenBoot
PROM firmware method of booting.
stop /SYS; start /SYS
powercycle
[
-f
]
The
-f
option forces an immediate
poweroff. Otherwise the command
attempts a graceful shutdown.
Performs a
poweroff
followed by
poweron
.
stop /SYS
poweroff
[
-y
] [
-f
]
•
-y
enables you to skip the
confirmation question.
•
-f
forces an immediate
shutdown.
Powers off the host server.
start /SYS
poweron [-c]
•
-c
executes a
console
command
after completion of the
poweron
command.
Powers on the host server.
set /SYS/P
S
x
prepare_to_remove_action=
tru
e
removefru /SYS/PS0 |
/SYS/PS1
Indicates if it is okay to perform a
hot-swap of a power supply. This
command does not perform any
action. But this command provides
a warning if the power supply
should not be removed because the
other power supply is not enabled.
reset /SYS
reset
[
-y
] [-c]
•
-y
enables you to skip the
confirmation question.
•
-c
executes a
console
command
after completion of the
reset
command.
Generates a hardware reset on the
host server.
reset /SP
resetsc
[
-y
]
•
-y
enables you to skip the
confirmation question.
Reboots the service processor.
set /SYS keyswitch_state=
value
normal | standby | diag |
locked
setkeyswitch [-y]
value
normal
|
standby
|
diag
|
locked
•
-y
enables you to skip the
confirmation question when
setting the keyswitch to
stby
.
Sets the virtual keyswitch.
TABLE:
Service-Related Commands
(Continued)
ILOM Command
ALOM CMT Command
Description