Keyboard LEDs (if a keyboard is present)
You can also obtain a summary of POST results by using the
.post
and
.rsc
commands.
Observing POST in Progress
As POST runs, it displays detailed diagnostic status messages on the system console
(or on an RSC console, if POST output has been redirected to an RSC console). If
POST detects an error, it displays an error message on either the system console or
the RSC console that indicates the failing part. A sample error message is provided
below:
Power On Self Test Failed. Cause: DIMM U0702 or System Board
ok
POST status and error conditions are indicated by the general fault LED on the
system front panel. The LED blinks slowly to indicate that POST is running. It
remains lit if POST detects a fault.
If a Sun Type-5 keyboard is attached, POST status and error indications are also
displayed via the four LEDs on the keyboard. When POST starts, all four keyboard
LEDs blink on and off simultaneously. After that, the Caps Lock LED blinks slowly to
indicate POST is running. If an error is detected, the pattern of the lit LEDs provides
an error indication. See “Error Indications” on page 257 for more information.
If POST detects an error condition that prevents the system from booting, it will halt
operation and display the
ok
prompt. The last message displayed by POST prior to
the
ok
prompt indicates which part you need to replace.
Obtaining a Summary of POST Results
Use the
.post
command at the
ok
prompt to view a summary of POST results.
ok .post
System status: OK
CPU0:
OK
CPU1:
OK
SC-MP:
OK
Psycho@1f:
OK
Cheerio:
OK
SCSI:
OK
Mem Bank0:
OK
Mem Bank1:
OK
Mem Bank2:
OK
Mem Bank3:
OK
PROM:
OK
NVRAM:
OK
TTY:
OK
SuperIO:
OK
238
Sun Enterprise 250 Server Owner’s Guide
♦
Revision A, June 1998
Summary of Contents for Enterprise 250
Page 2: ...USA 650 960 1300 fax 650 969 9131 ...
Page 3: ...Sun Enterprise 250 Server Owner s Guide Part No 805 3389 11 Revision A June 1998 ...
Page 44: ...10 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 45: ...CHAPTER 2 Photographic Tour of System System View 11 ...
Page 48: ...Figure 2 2 14 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 52: ...Figure 2 4 18 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 69: ...Power Distribution Board Photographic Tour of System 35 ...
Page 88: ...54 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 102: ...68 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 160: ...126 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 212: ...178 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 226: ...Figure 9 8 192 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 228: ...194 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 266: ...232 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 310: ...276 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 324: ...290 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 330: ...296 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 346: ...312 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Page 356: ...TABLE D 6 continued 322 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...