Chapter 4
I/O+ Boards and Components
4-13
FIGURE 4-10
Enterprise 5500/4500 Board Locations
4.5.3.2
Cooling and Power Issues
There should be one power/cooling module (PCM) for every two boards to adhere
to cooling and power requirements. The PCMs must be installed adjacent to
populated board slots to ensure the fan in the PCM can cool the respective boards.
Note –
All empty board slots in Enterprise 6500 systems must have a load board
installed to ensure proper cooling and for EMI protection. All empty board slots in
Enterprise 5500 or 4500 systems must have a filler panel installed.
Slot #
0
2
4
6
Slot #
1
3
5
7
PCM
Front View
Rear View