5
3.
Electric Wiring Diagram
Options for protecting devices and cable specification
※
Above data is subject to modification without notice.
Note:
The above data is adapted
to power cord ≤
10m. If power cord is
>
10m, wire
diameter must be increased. The signal cable can be extended to 50m at
most.
4.
Installation instruction and requirement
The heat pump must be installed by a professional person, otherwise the heat pump
might be damaged and risky users safety.
A.
Installation
1) The inlet and outlet water unions can
’
t bear the weight of soft pipes. The heat
pump must be connected with hard pipes!
2) In order to guarantee the heating efficiency, the water pipe length should be
≤10m between the pool and the heat pump.
MODEL
Summerwave
6.5 Si
Summerwave
8.0 Si
Summerwave
9.0Si
Summerwave
12.5 Si
Summerwave
16.5 Si
Summerwave
20.5 Si
Summerwave
25.0 Si
Breaker
Rated
Current
A
8.0
9.5
11.5
15.0
18.0
23.0
25.0
Rated
Residual
Action
Current
mA
30
30
30
30
30
30
30
Fuse A
8.0
9.5
11.5
15.0
18.0
23.0
25.0
Power Cord
(mm
2
)
3×1.5
3×1.5
3×2.5
3×2.5
3×4
3×4
3×6
Signal cable
(mm
2
)
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5