2
III.
Technical Parameter
Model
Summerwave
6.5 Si
Summerwave
8.0 Si
Summerwave
9.0Si
Summerwave
12.5 Si
Summerwave
16.5 Si
Summerwave
20.5 Si
Summerwave
25.0 Si
Advised pool volume(m
3
)
14~28
20~35
20~40
30~55
35-70
45-85
55-100
Operating air
temperature (
℃
)
0~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
6.5
8.0
9.2
12.5
16.5
20.5
25.0
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
4.5
6.0
7.0
9.0
11.5
14.0
17.0
Rated input power
at air 15°C (kW)
0.35~1.0
0.34~1.40
0.34~1.6
0.36~2.0
0.56~2.7
0.6~3.4
0.68~3.95
Rated input current
at air 15°C (A)
1.52~4.4
1.48~6.0
1.48~7.0
1.57~8.7
2.43~11.7
2.6~15.0
2.95~17.1
Power supply
230V/1 Ph/50Hz
Advised water flux
(m³/h)
2~4
2~4
3~4
4~6
6~8
8-~10
10-~12
Water pipe in-out Spec
(mm)
50
Net Dimension LxWxH
(mm)
872×349×
654
872×349×
654
872×349×
654
872×349×
654
962×349×
654
962×349×
754
1092×420×
958
Net Weight(kg)
42
46
47
49
60
68
90
Notice:
1.
This product can work at air temp 0
℃~
+43
℃
, efficiency will not be guaranteed
out of this range or at low temperatures. Please take into consideration that the pool
heater performance and parameters are different under various conditions.
2.
Related parameters are subject to adjustment periodically for technical
improvement without further notice. For details please refer to nameplate.
Summary of Contents for 12.5 Si
Page 1: ...INVERTER SWIMMING POOL HEAT PUMP ...
Page 2: ......
Page 18: ...15 XI Appendix 1 Heating priority Optional ...
Page 19: ...16 XII Appendix 2 Heating priority Optional ...
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ...Version Cb9IN 1 ...