Summary of Contents for 12.5 Si

Page 1: ...INVERTER SWIMMING POOL HEAT PUMP ...

Page 2: ......

Page 3: ...meter 2 IV Dimension 3 V Installation instruction 4 VI Operation instruction 8 VII Testing 10 VIII Precautions 11 IX Maintenance 12 X Trouble shooting for common faults 13 XI Appendix 1 Heating priority Optional 15 XII Appendix 2 Heating priority Optional 16 ...

Page 4: ...temp efficiently and economically to provide you comfort and pleasure 2 User may choose the model technical parameter according to professional guide this series of swimming pool heater has been optimized in factory refer to technical parameter table II Features 1 High efficient titanium heat exchanger 2 Sensitive and accurate temp control and water temp display 3 High pressure and low pressure pr...

Page 5: ...3 4 0 68 3 95 Rated input current at air 15 C A 1 52 4 4 1 48 6 0 1 48 7 0 1 57 8 7 2 43 11 7 2 6 15 0 2 95 17 1 Power supply 230V 1 Ph 50Hz Advised water flux m h 2 4 2 4 3 4 4 6 6 8 8 10 10 12 Water pipe in out Spec mm 50 Net Dimension LxWxH mm 872 349 654 872 349 654 872 349 654 872 349 654 962 349 654 962 349 754 1092 420 958 Net Weight kg 42 46 47 49 60 68 90 Notice 1 This product can work at...

Page 6: ...tment periodically for improvement without further notice UNIT MM A B C D E F G H MODEL Summerwave 6 5Si 324 560 330 349 872 330 74 654 Summerwave 8 0Si 324 560 330 349 872 250 74 654 Summerwave 9 0Si 324 560 330 349 872 250 74 654 Summerwave 12 5Si 324 560 330 349 872 290 74 654 Summerwave 16 5Si 324 590 330 349 962 350 74 654 Summerwave 20 5Si 324 590 325 349 962 350 74 754 Summerwave 25 0Si 395...

Page 7: ...eference 2 Connecting your power wire Note Must be hard wired no plug allowed In Australia Summerwave 6 5Si and Summerwave 12 5Si has plug as optional The swimming pool heater must be earthed well For power supply 230V 50Hz Distribution Box Customer prepare Power Cord Swimming Pool Heat Pump Wiring Board Power Supply 230V 50Hz Breaker Fuse Earthing ...

Page 8: ...y A Installation 1 The inlet and outlet water unions can t bear the weight of soft pipes The heat pump must be connected with hard pipes 2 In order to guarantee the heating efficiency the water pipe length should be 10m between the pool and the heat pump MODEL Summerwave 6 5 Si Summerwave 8 0 Si Summerwave 9 0Si Summerwave 12 5 Si Summerwave 16 5 Si Summerwave 20 5 Si Summerwave 25 0 Si Breaker Ra...

Page 9: ...t will block air flow near inlet or outlet area and there is no barrier within 50cm behind the main machine or the efficiency of the heater can be reduced or even stop 4 When the machine is running there will be condensation water discharged from the bottom Connect drainage nozzle accessory into the hole under the machine and clip it in then connect the clear plastic pipe to drain the condensation...

Page 10: ...tage of the products 2 Earth the machine well 3 Wiring must be handled by a professional technician according to the circuit diagram 4 Set leakage protector according to the local code for wiring leakage operating current 30mA D Switch on after finishing all wiring construction and re checking ...

Page 11: ...o some models will heat only Fan Press to select Smart Silence mode Smart mode 100 20 capacity Silence mode 80 20 capacity Note You may set the desired water temperature from 12 to 40 The on the right shows the inlet water temperature The on the left shows the outlet water temperature After you turn on the heat pump the fan will start to run in 3 minutes In another 30 seconds the compressor will s...

Page 12: ...f NOTE Do not set timer unless a separate dedicated water pump is going to be used Press the for 10 seconds to enter the timer setting The ON will be flashing to enter the Timer ON setting Press the and to adjust Timer ON time You can choose Timer on Display ON or Repeat Timer ON display 1 ON by pressing Then press to confirm When the ON stops flashing and OFF is flashing you enter the Timer OFF m...

Page 13: ...ress both and buttons for 5 seconds to start compulsory defrost Note the break between compulsory defrost needs to be more than 30 minutes The symbol of defrost is twinkling when machine is compulsory or auto defrost The period and ending of compulsory defrost is the same as auto defrost VII Testing 1 Inspection before use A Check installation of the whole machine and the pipe connections accordin...

Page 14: ...w near inlet or outlet area or the efficiency of the heater will be reduced or even stop C Do not put hands into outlet of the swimming pool heater and do not remove the screen of the fan at any time D If there are abnormal conditions such as noise smell smoke and electrical leakage please switch off the machine immediately and contact the local dealer Don t try to repair it yourself E Don t use o...

Page 15: ...lightning D If the machine is stopped for a long time please cut off the power supply and drain water clear of the machine by opening the tap of inlet pipe IX Maintenance A In winter season when you don t swim 1 Cut off power supply to prevent any machine damage 2 Drain water clear of the machine 3 Cover the machine body when not in use Cut off power supply of the heater before cleaning examinatio...

Page 16: ...but with insufficient heating evaporator blocked Remove the obstacles Air outlet blocked Remove the obstacles 3 minutes start delay Wait patiently Display normal but no heating Set temp too low Set proper heating temp 3 minutes start delay Wait patiently If above solutions don t work please contact your installer with detailed information and your model number Don t try to repair it yourself Note ...

Page 17: ...0 Controller communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp sensor failure 12 P5 Gas return temp sensor failure 13 P6 Cooling coil pipe temp sensor failure 14 P7 Ambient temp sensor failure 15 P8 Cooling plate sensor failure 16 P9 Current sensor failure 17 PA Restart memory failu...

Page 18: ...15 XI Appendix 1 Heating priority Optional ...

Page 19: ...16 XII Appendix 2 Heating priority Optional ...

Page 20: ... clock A Water pump timer B Water pump wiring of Heat Pump Note The installer should connect A parallel with B as above picture To start the water pump condition A or B is connected To stop the water pump both A and B should be disconnected ...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...Version Cb9IN 1 ...