S One
User’s Manual
OPOS
3-6
The parameter OPOS origin is created to automate the start of the OPOS procedure. This
parameter has 4 settings. The usage of this parameter depends on the chosen OPOS mode.
If the OPOS is OPOS barcode or OPOS Sheet, then this parameter does not affect.
The useful combinations are visible in the below table.
OPOS X
OPOS XY
Mark
‘Indicate Mark’
‘Indicate Mark’
XY line
-
‘Indicate Line’
Current Position
‘Current Position’
‘Current Position’
Media centre
-
‘Center of media’
The
OPOS Origin is set to ‘Mark’.
This is the default setting. Upon receiving an OPOS job from the computer, the cutter will
prompt the user to set the tool above the first mark and press Apply. The cutter will then start
searching for the OPOS mark around that position.
The
OPOS Origin is set to ‘Current position’.
Upon receiving an OPOS job from the computer, the cutter will immediately start looking for
the mark when it receives an OPOS job from the computer, without waiting for the user to move
the tool. Therefore, the user will have to set the tool above the first mark while loading the
material.
If the OPOS origin is set to either ‘XY
-
correction line’ or ‘Center of media’, then the cutter will
react as if
the parameter was set to ‘Indicate mark’
.
The
OPOS Origin is set to ‘Mark’.
This is the default setting. Upon receiving an OPOS job from the computer, the cutter will
prompt the user to set the tool above the first mark and press Apply. The cutter will then start
searching for the OPOS mark around that position.
The
OPOS origin is set to ‘
XY
line’
Upon receiving an OPOS job from the computer, the cutter will prompt the user to set the tool
under the OPOS XY line and press Apply. The cutter will then start searching for the OPOS XY
line by slowly moving forward the media. Once it has found the OPOS XY line, it will follow this
line to the right until it finds the first mark and will then start searching for the actual mark.
3.3.1
OPOS origin
3.3.1.1
In combination with OPOS X mode
3.3.1.2
In combination with OPOS XY mode