2-17
2.Basic splicing operation
|
Optical fiber splicing
2. Basic splicing operation
●
Starting the automatic splice
Here is a summary of the splicing operation procedures.
1: Slip a protection sleeve over the fiber.
2: Strip the fiber coating and clean the
fiber. If you have performed an arc test,
prepare the fiber again.
▸
P.2-11 Stripping the fiber coating
▸
P.2-12 Cleaving the fiber
3: Load a prepared fiber in the fiber coating clamp of the fusion splicer.
(
▸
P.2-14)
Tap the Set icon
(
)
or press the Set key
( )
to start splicing.
2: Inspection of fiber end face &
dust.
4: Estimated loss is displayed.
After the splicing
process is complete,
▸
Checking splice image and data P.2-18
▸
Splice error possible cause and troubleshooting P.2-19
▸
Proof test P.2-20
■
Making a splice
Be sure to slip the fiber protec-
tion sleeve over one of the fibers
to be spliced before stripping and
cleaving the fibers. The fiber pro-
tection sleeve cannot be installed
after splicing.
1: Tap the Set icon (
).
3: Arc is generated.