SECTION 6
WS CONTROLLER USER INTERFACE MANUAL
45
V37
Device Change
(same type)
• option board changed
• different power rating of drive
Reset Controller.
Note
: On reset, no Fault Time Data
Record is made.
Note
: On reset, application parameter
values are restored to default.
V38
Device Added (same
type)
• option board added
• drive of different power rating added
Reset Controller.
Note
: On reset, no Fault Time Data
Record is made.
Note
: On reset, application parameter
values are restored to default.
V39
Device Removed
• option board removed
• drive removed
Reset Controller.
Note
: On reset, no Fault Time Data
Record is made.
Note
: On reset, application parameter
values are restored to default.
V40
Device Unknown
Unknown option board or drive
Contact Sullair service.
V41
IGBT Temperature
IGBT Inverter Bridge overtemperature
protection has detected a high short-
term overload current
Check loading. Check motor size.
V42
Brake Overtemp
This fault is disabled. A display of this
message indicates that the
components or settings of the variable
frequency drive have been changed.
Correct drive parameters need to be
downloaded. Contact Sullair service.
V43
Encoder Fault
This fault is disabled. A display of this
message indicates that the
components or settings of the variable
frequency drive have been changed.
Correct drive parameters need to be
downloaded. Contact Sullair service.
V44
Device Change
(different type)
• option board changed
• different power rating of drive
Reset Controller.
Note
: On reset, no Fault Time Data
Record is made.
Note
: On reset, application parameter
values are restored to default.
V45
Device Added
(different type)
• option board added
• drive of different power rating added
Reset Controller.
Note
: On reset, no Fault Time Data
Record is made.
Note
: On reset, application parameter
values are restored to default.
V50
Analog Input
Current at the analog input is< 4 mA
Adjust analog input parameter to "None".
V51
External fault
Digital input set as an external fault
input has been triggered
Clear the package emergency stop.
Check E-stop wiring to the drive input.
V52
Keypad Comm
The variable frequency drive parts or
settings have been changed.
Drive parameters need to be
downloaded. Contact Sullair service.
V53
FieldBus
The data connection between the
communication bus master and the
communication bus board has failed
Check WS Controller bus cable. If
installation is correct contact Sullair
service.
Table 6-3: VSD Troubleshooting Guide—Drive Faults
CODE
FAULT
POSSIBLE CAUSE
SOLUTION
Summary of Contents for 02250165-411 R01
Page 10: ...10 BLANK PAGE...
Page 14: ...14 BLANK PAGE...
Page 26: ...26 BLANK PAGE...
Page 34: ...34 BLANK PAGE...
Page 47: ...47 BLANK PAGE...