ProntoPress-20
Instruction Manual
37
The machine can count the preheating and heating time either
from start or from when the pre-set temperatures are reached.
To set the Counting mode for heating time: See Software Settings,
Setting the Countdown Mode.
The cooling time is always counted from start of cooling.
The machine can count through the cooling with all three
different cooling rates.
ECONOMY cooling rate will only allow 20% of the water flow
during the whole cooling period, compared to fully
open circulation (cooling rate: HIGH).
The cooling time will be slightly longer than for
cooling rate: HIGH.
LOW
cooling rate will only allow 2% of the water flow in
the first 3 minutes of the cooling period, then 20% of
full flow.
This will allow for a very uniform cooling of the
mount, thus reducing the internal stress in the resin.
The cooling time will in some cases be slightly longer
than for cooling rate: HIGH.
HIGH
cooling rate will give full flow during the whole
cooling period. This gives a very rapid cooling.
Heating Time
Cooling
20
40
60
80
100
120
140
160
180
Temp
°C
0
1
2
3
4
5
6
7
Time [min]
High
Low
Economy
Cooling Gradients
Summary of Contents for ProntoPress-10
Page 1: ...Manual No 15077003 Date of Release 11 01 2008 ProntoPress 20 Instruction Manual ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 60: ...ProntoPress 20 Gebrauchsanweisung Handbuch Nr 15077003 Auslieferungsdatum 11 01 2008 ...
Page 61: ......
Page 63: ......
Page 65: ......
Page 121: ...ProntoPress 20 Mode d emploi Mode d emploi no 15077003 Date de parution 11 01 2008 ...
Page 122: ......
Page 124: ......
Page 126: ......
Page 187: ......
Page 188: ......
Page 189: ......
Page 190: ......
Page 191: ......
Page 193: ......