Original assembly/operating instructions Gear limit switch Type series 51 • No. 151-00004 H • 01.2018
31
It
e
m
n
o
.
N
u
m
b
e
r
o
f
s
c
re
w
s
P
o
s
it
io
n
S
c
re
w
s
T
ig
h
te
n
in
g
to
rq
u
e
(3)
4
Housing
side
see operat-
ing instruc-
tions of the
machine.
see operat-
ing instruc-
tions of the
machine.
(4)
3
Input side
M5, 9 mm
deep
5 Nm
It
e
m
no
.
N
um
be
r
of
s
c
re
w
s
P
os
it
ion
S
c
re
w
s
Ti
gh
te
ni
ng
tor
qu
e
(2)
3
Input side
M6, 8 mm
deep
2.5 Nm
6.3.2
Housing assembly, IP65
Mount the GCLS on the machine
1. The connection between the drive shaft (1) of the GCLS and the machine must be positively locked.
2. Depending on the installation conditions: Mount the GCLS on the housing or input side using screws
3. For adjusting switching points, see section 6.6.2.
4. Mount the housing cover, see section 6.7.
6.3.3
Housing assembly, IP66
Mount the GCLS on the machine
1. The connection between the drive shaft of the GCLS and the machine must be positively locked.
2. Mount the GCLS (1) with screws.GCLS maschinenseitig montieren
3. For adjusting switching points, see section 6.6.2.
4. Mount the housing cover, see section 6.7.
Fig. 14
Fig. 15