6
EWS150 Configuration Guide
EWS150 Configuration Guide
About the Country Code
The country code used by the EWS150 is determined by the SKU (Stock Keeping Unit) you ordered. For
example, if you ordered the North American version of the EWS150 the country code is preset to UNITED
STATES, with the option of changing this setting to CANADA. Country codes are predetermined to ensure full
compliance with local regulatory laws for wireless communications.
Setting Up the User Login Parameters
Establishing user login parameters determines both the administrator and guest user privileges. To set up these
parameters, click on the
Configure
tab then click on
User Login
to display the User Login window.
Figure 6. User Login Window
1.
In the User Name field, select the type of user (either Admin or Guest) from the pull-down list.
2.
In the Password field, enter a password (between 5 and 32 characters). The password is case-
sensitive.
3.
In the Confirm Password field, retype your password (otherwise the system will reject it).
The default for the user name and the password is
Admin
(with a capitalized A) for both. We strongly
recommend that you change the default password immediately after your initial login.
4.
In the Guest User Login field, check the enabled box if you want to allow guest access. Leave this box
unchecked to deny all guess access.
5.
When finished, click on
Update
to apply your changes then click on
Reboot
to reboot the EWS150.
Only after the unit reboots will the user login parameters you defined here be in effect.