8
Overview
Control technical data
Mains power supply
230V +10/-15% / 50Hz
Power consumption, electronics
max. 30VA at 230V
Maximum current consumption, entire system
Imax = 6.3 A
Fuse use
5 x 20 mm / 6.3 A quick-blow
Switch-off temperature of the safety temperature limiter
T = 100
C +0 / -5%
Heating circuit pump
Switching output: 230 V / max. 1.5 A
Charge pump for tap water storage tank
Switching output: 230 V / max. 1.5 A
Actuator drive for charge valve
Switching output: 230 V / max. 0.1 A
Induced draft fan
Switching output: 230 V / max. 1.5 A
Primary pump
Switching output: 230 V / max. 1.5 A
Actuator drive for return valve
Switching output: 230 V / max. 0.1 A
Floating switchover contact
Contact load: 230 V / max. 5 A
Control outputs for air regulator units
0 to 10 V / max. 3 mA
Power supply output for air regulator units
AC voltage output: 24 V / 6 VA
Electromagnetic door opener
AC voltage output: 12 V / 16 VA
Power supply output for O
2
probe
AC voltage output: 12 V / 16 VA
Measurement input for Pt100 (R=108/20
C)
- Storage tank sensor
- boiler sensor
- exhaust fume sensor
Maximum sensor temperature:
Tmax = 150
C
Tmax = 150
C
Tmax = 600
C
Immersion sleeve for boiler sensor and safety temperature
limiter
2x LW7 with cable ties
Ms63, PN16, immersion depth 100
Protection class
IP 40 (appliance detached: IP 00)
Ambient operating temperature
0
C to +50
C
Ambient storage temperature
–20
C to +70
C
There are several controllers available in the Strebel Turbotec boiler range, each with their own special features. These controllers DO NOT
alter the performance of the appliance, only supplementing system/control outputs.
Covered in this manual is LC1.