Removing a U779V Fabric Switch
A-4
Stratus ftServer V 6624 Hardware Installation Guide
(R005S)
b. Issue the
board_admin
command, specifying the correct device ID for the
device_id
argument and
remove
for the
action
argument, as follows:
board_admin
device_id
remove
N O T E
You must be logged in as
SysAdmin
in order to issue the
board_admin
command.
c. Confirm that the U779V fabric switch has been removed from service by
issuing the
list_boards -long
request of the
analyze_system
subsystem. The value listed in the
State
row should be
STATE_REMOVED
.
5. Standing at the front of the cabinet, move the two power switches on the rear of the
fabric switch to the 0 (off) position (
).
N O T I C E
Power off only the
failed
fabric switch. Do not power off
the working fabric switch.
Figure A-3. Turning Off Power
1
Power switches
1
poweroff