Appendix – Specifications
Reserve Power
116
Strata CIX General Description
Reserve Power
Two or four customer-supplied 12VDC reserve batteries (80 ampere-hours max.) can be connected
to either system to maintain normal operation during a power failure (see
Tables 11
~
14
). The
batteries are kept in a highly-charged state by the power supply’s battery charger and must be
connected when the system is operating normally. Fully charged batteries must be connected when
normal AC power is available, batteries cannot be connected after/during an actual power failure.
The battery charger is standard on the CIX670 and CIX1200 power supply. An optional ABCS
battery charger must be used in the CIX100 power supply.
Reserve Power
1
Table 11
CIX100 Typical Reserve Power Duration Estimates
1. Assumes 80 ampere-hours with 12VDC batteries.
Number of Cabinets
1
2
Estimated operation time: two-battery configuration
25 hr.
12.5 hr.
Estimated operation time: four-battery configuration
50 hr.
25 hr.
DC Current Drain (-24VDC)
3.15 amps.
6.30 amps.
Table 12
CIX670 Reserve Power Characteristics
Battery Charger Characteristics
Maximum Battery Charger Drain (-24VDC)
Charger: current limiting
Nominal float voltage: 2.275 volts/cell
Charge current: 0.7 amps maximum
Battery discharge cut-off voltage: 20.5 ±0.5VDC
1 cabinet
2 cabinets
3 cabinets
4 cabinets
6.0 amps
12.0 amps
18.0 amps
24.0 amps
5 cabinets
6 cabinets
7 cabinets
30.0 amps
36.0 amps
42.0 amps
Table 13
CIX1200 Reserve Power Characteristics
Battery Charger Characteristics
Maximum Battery Charger Drain (-24VDC)
Charger: current limiting
Nominal float voltage: 2.275 volts/cell
Charge current: 0.7 amps maximum
Battery discharge cut-off voltage: 20.5 ±0.5VDC
1 cabinet
2 cabinets
3 cabinets
4 cabinets
5 cabinets
6 cabinets
7 cabinets
6.0 amps
12.0 amps
18.0 amps
24.0 amps
30.0 amps
36.0 amps
42.0 amps
8 cabinets
9 cabinets
10 cabinets
11 cabinets
12 cabinets
6.0 amps
12.0 amps
18.0 amps
24.0 amps
30.0 amps
Note
Reserve power treatment for CIX1200 should be configured as two separate systems – one
7-cabinet stack and one 5-cabinet stack.