5.3 List of error code
Error Type
Error code
Description
Lamp status
Thermal relay
E01
Over-heating (1st thermal relay)
Yellow lamp (thermal
protection) always on
E02
Over-heating (2nd thermal relay)
Yellow lamp (thermal
protection) always on
E03
Over-heating (3rd thermal relay)
Yellow lamp (thermal
protection) always on
E04
Over-heating (4th thermal relay)
Yellow lamp (thermal
protection) always on
E09
Over-heating (Program in default)
Yellow lamp (thermal
protection) always on
Welding
machine
E10
Phase loss
Yellow lamp (thermal
protection) always on
E11
No water
Yellow lamp (lack
water) always on
E12
No gas
Red lamp always on
E13
Under voltage
Yellow lamp (thermal
protection) always on
5
No striking arc and no
output voltage
Output cable is connected
incorrectly or loosen
Screw it down or change it
Control circuit damaged
Check the circuit
6
Welding stops, and
alarm light is on
Machine has self-protection
Check over-voltage,
over-current, over-temperature,
lower-voltage and
over-temperature, and solve it
7
Welding current is run
away and can be not
controlled
The potentiometer damaged Check or change it
The control circuit
damaged
Check the circuit
8
The crater current can be
not adjusted
The PCB damaged
Check it
9
No post-gas
The PCB damaged
Check it
54
www.strata.co.nz
ADVANCEMULTI205P