Welding parameters available by press the knob
Welding parameters available by rotating the knob
Pre-flow
0.0-20.0(S)
Slow feed
0-10
Start Amp(current) P(percentage)
1-200
(
%
)
Start Amp(current) AL (arclength)
-10~10 (only for pulse mode)
Up Slope
0.0-20.0(S)
Welding Amp (current)
25-110 (110V)/25-200
(
230V
)
Down Slope
0.0-20.0(S)
End Amp(current) P(percentage)
1-200
(
%
)
End Amp(current) AL (arclength)
-10~10 (only for pulse mode)
Burn Back
0-10
Post-flow
0.0-20.0(S)
24
www.strata.co.nz
ADVANCEMULTI205P