Installation & Operation Guide
Contact Power Pack Sensor System
24
Display
The Display feature allows the programmer to visually and audibly verify the programmed
feature parameters.
To enter Display Mode:
Step 1. Enter Programming Mode (refer to page 16).
Step 2. Select the field you wish to verify.
Step 3. Press DISP button.
Step 4. Tap button for each available setting for the chosen field. The sensor will blink
red
indicating that the setting is not programmed for the sensor, or
blue
indicating that
the setting is programmed to the sensor.
Step 5. Press DISP button again to exit Display Mode.
Example
: To see the time-out period of a sensor: Press TIME, then DISP. Toggle through the
time selections until the sensor blinks
blue
to indicate the programmed time-out period.