Step 5. Select activation mode:
Exit programming by pressing the PGM/EXIT button or continue with programming by
selecting another field.
Time (Blue)
The TIME field allows selection of the time-out period after the sensor no longer detects occu-
pancy. Periods may be selected from 1 to 30 minutes.
Note:
Increasing the time delay will lower the possibility of a false Off trigger, but will also
lower the energy savings.
To change the time of the sensor:
Step 1. Enter Programming Mode (refer to page 16).
Step 2. Press TIME button.
Step 3. Select time-out period by pressing the appropriate button.
Exit programming by pressing the PGM/EXIT button or continue with programming by
selecting another field.
Button 5
Manual ON
Button 6
Automatic ON
* Factory Default
Button 7
Factory Default
Manual ON
* Sets all Occupancy Sensor parameters to
Factory Defaults (Must press and hold either
button for 3 seconds)
Button 8
Factory Default
Automatic ON
Button 0
Factory Default
* Sets Fixed Timing, Automatic ON
Button 1
1 Minute
Button 2
3 Minutes
Button 3
5 Minutes
Button 4
10 Minutes
Button 5
15 Minutes
* Factory Default
Button 6
20 Minutes
Button 7
25 Minutes
Button 8
30 Minutes
Button 0
Factory Default
* 15 Minutes
Summary of Contents for Contact Power Pack
Page 1: ......
Page 47: ...Contact Power Pack Sensor System Installation Operation Guide 45 NOTES...
Page 48: ...Part No 2 450213 010...