Installation & Operation Guide
Contact Power Pack Sensor System
10
Installation
The Ceiling Occupancy Sensor may be mounted in a junction box or directly to the ceiling
depending on local code. The unit must have an unobstructed view of the area to be monitored
and
must be
mounted perpendicular to the floor below. If the unit is subject to "false trigger-
ing" from activity beyond the desired area of coverage, a portion of the lens may be masked to
achieve the desired response. Simply install the Field of View Customizing Template (pro-
vided).
To install:
Step 1. Check for any obstructions located behind the desired mounting location.
Step 2. Drill 1-1/2 inch hole in the desired mounting location.
Step 3. Place Ceiling Occupancy Sensor through the hole and secure with supplied washer
and locknut.
Step 4. The lens may be removed to install the Field of View Customizing Template*.
Simply rotate the lens cover slightly counter-clockwise and remove.
Step 5. Trim the template for the desired effect and install on interior of the lens. (Careful
placement of the template is necessary to ensure proper function.)
Step 6. Replace lens cover and verify that the unit is securely mounted.
Note:
Sensors must be mounted perpendicular to the floor.
Figure 2: Ceiling Occupancy Sensor Installation
*
The Field of View Customizing Template is used to block the Occupancy Sensor
in areas where motion should not trigger the sensor.
RETAINING NUT
WASHER
LOW VOLTAGE
WIRE