3.5" 3Gbps-Speed SATA Mirror Drive Model User’s Manual
1.5 Revival Reconstruction
When an error occurs in a drive unit and the mirror controller cannot get the response from the drive for
30 seconds, the controller will issue the reset command to the drive and check its status again.
If the drive recovers, the
SATA Mirror Drive
returns to the normal operation. But if not, the controller
treats the drive as a failed drive.
The function “Revival Reconstruction” turns the power of the drive OFF/ON. And if the drive status
becomes ready, reconstruction is started.
Revival reconstruction is executed up to two times. After the same error occurs three times, the
SATA
Mirror Drive
will remain in Degraded Mode. Then the failed drive status indicator (LED) will light orange.
The function can be enabled /disabled by Dip Switch. Factory default is “enabled”.
The
SATA Mirror Drive
still responds to the host normally even during reconstruction. After the
reconstruction is finished, the
SATA Mirror Drive
returns to normal mode automatically.
3