Enable Door Monitoring (Door 1 only)
In its factory fitted format, the door sensor is disabled. This is because the hard wire bridge is connected
between terminals 9 and 1 (0V Return and the Door Sensor).
This disables the door forced alarm feature. To utilise the door sensor, remove the hard wire bridge and
connect the door sensor to terminals 1 and 9.
Activating the ‘Operator Under Duress’ Alarm
The Operator Under Duress Alarm can be activated at any time by prefixing a valid entry code with
the numbers 9 1. Note: if there is any possibility that this feature will be used, any visible or audible alarm
indicators must be located out of audible and visual range of any attacker or intruder.