F.A.Q’s
1/ The door is locked when it should be open and open when it should be locked.
2/ The Keypad appears to have lost it's entry codes
3/ How do I add and delete codes ?
4/. What power supply do I need for a Strikemaster?
5/ I want to fit a separate door bell.
6/ I want to disable the alarm and open the door with a single code can I do this?
7/ There is a continuous clicking noise.
8/ The door opens for too long.
9/ What are the door release relays rated at ?
1/ The door is locked when it should be open and open when it should be locked.
Check the type of lock that is installed. Does it require power to open it or power to lock it? This will
determine which keypad terminals should be connected.
If the lock requires power to open it then the lock should be connected to “zero volts” and “relay 1 Normally
open” ( Terminals 1 and 3 )
If the lock requires power to lock it, i.e. a Magnetic Lock, it should be connected to the “zero volts” and “relay
1 Normally closed” ( Terminals 1 and 5 ).
In both the above cases it is assumed that power is being switched through the relay in which case the “relay
common” should be connected to the “positive power supply” (i.e. 4 and 2 should be
connected.)