Programming : Adding and Removing User Codes 
 

To add or remove entry codes  : log on to enter Programming Mode, then follow the appropriate command 
sequence detailed on the following page. 
a). Entry Codes should not start with numbers 9 or 1. 
b). Each entry code recognised by the keypad is stored under a two digit reference known as the Code Index 
Number. The code index number allows an authorised holder of the engineer’s code to remove entry codes 
by keying in the code index number without having knowledge of the actual entry code. It also means that a 
written record of valid code holders can be kept without recording the actual entry codes 
c). Prior to operation of a second door, relay 2 must be set for door control see - Controlling a Second  Door 
 
 

Code 
Index 

Number 

Users Name 

Door  

1 or 2 

Latched

or 

Timed 

Code 

Index 

Number

Users Name 

Door 

1 or 2 

Latched

or 

Timed 

00  

 

 

25  

 

 

01  

 

 

26  

 

 

02  

 

 

27  

 

 

02  

 

 

28  

 

 

04  

 

 

29  

 

 

05  

 

 

30  

 

 

06  

 

 

31  

 

 

07  

 

 

32  

 

 

08  

 

 

33  

 

 

09  

 

 

34  

 

 

10  

 

 

35  

 

 

11  

 

 

36  

 

 

12  

 

 

37  

 

 

13  

 

 

38  

 

 

14  

 

 

39  

 

 

15  

 

 

40  

 

 

16  

 

 

41  

 

 

17  

 

 

42  

 

 

18  

 

 

43  

 

 

19  

 

 

44  

 

 

20  

 

 

45  

 

 

21  

 

 

46  

 

 

22  

 

 

47  

 

 

23  

 

 

48  

 

 

24  

 

 

49  

 

 

Summary of Contents for AXS Strikemaster

Page 1: ...Strikemaster Engineering Manual AXS Strikemaster Programming and Operation Manual May 2013 Page 1 of 22 For more information visit www storm interface com Copyright Storm Interface 2013 All rights reserved ...

Page 2: ...r Strike Time 13 Programming Set the Penalty Time for Invalid Code 14 Other Features 15 Connect a Remote Exit Egress Switch 15 Connect an External Alarm 15 Control a Second Door 15 Enable Door Monitoring Door 1 only 16 Activating the Operator Under Duress Alarm 16 F A Q s 17 1 The door is locked when it should be open and open when it should be locked 17 2 The Keypad appears to be have lost its en...

Page 3: ...es and Benefits A range of access control keypads providing rapid and reliable access control in high traffic applications Constructed to withstand hard use and abuse the keypads can be fitted in exposed unsupervised locations Up to 50 different 4 5 or 6 digit pin codes can be programmed and each code can be set to trigger an electric lock or strike for a pre set time One or two door control Weath...

Page 4: ...ase Material Keytop Material DE1KT101 STORM AXS STRIKE MASTER ANTI VANDAL KEYPAD Two Relays Metal Case Metal Keytops DE2KT101 STORM AXS STRIKE MASTER ROBUST KEYPAD Two Relays Polymer Case Polymer Keytops White DEPLXT201 PLX STRIKE MASTER STORM 1000 SERIES Two Relays Polymer Case Metal Keytops DR2KT201 STORM AXS STRIKE MASTER ROBUST SINGLE DOOR KEYPAD One Relay Polymer case Polymer Keytops Black RC...

Page 5: ...013 Page 5 of 22 For more information visit www storm interface com Copyright Storm Interface 2013 All rights reserved Dimensions What s in the Box Keypad DE1K shown Back Box Gasket Programming Chart Security Screws Driver Bit for Security Screws Tamper Bracket Screws Plugs for Backbox fixing ...

Page 6: ...positioning the case over the fixing holes A Be sure to run the cable through the hole in the gasket prior to securing the case 5 Secure the case to the surface using the fixing screws E as supplied Keypad to Casing 6 When making the electrical connections to the connector block care should be taken not to damage the thin sealing gasket C fixed to the front face of the rear case 7 Fix the keypad t...

Page 7: ...ct relay normally open or relay normally closed to suit the intended application and locking mechanism Note To achieve maximum protection against EMC RFI or damage from Electro static Discharge it is recommended that the keypad casing is earthed grounded via the screw terminal attached to the metal shield on the rear face of the keypad This terminal is identified by a symbol It is recommended that...

Page 8: ... outdoor or indoor access points to establish and maintain familiarity with the keypad features Summary of Features Up to 50 user programmable entry codes Entry Code indexing system provides a directory of authorised code holders and permits secure allocation and re allocation of entry codes 4 5 or 6 digit entry codes One or two door control Anti tamper alarm Entry code entered under duress alarm ...

Page 9: ...ght green to signify that the door lock is in a released or open condition Programing Mode To enter programming mode it is required that the operator logs on by entering the engineer s code When logging on the engineer s code must be preceded by the key If the code is correct the LED will start flashing red and green alternately to signify that the operator has logged on and that the keypad is in ...

Page 10: ...ngineer s code is not known power down the keypad for a period of not less than three seconds Power up the keypad and within a two minute period enter the Engineer reset code Do not enter any other digits before entering this code The keypad s LED will then begin flashing to indicate that the keypad is in programming mode Enter 4 to select a new engineer s code If code is not known Power Down then...

Page 11: ... digit reference known as the Code Index Number The code index number allows an authorised holder of the engineer s code to remove entry codes by keying in the code index number without having knowledge of the actual entry code It also means that a written record of valid code holders can be kept without recording the actual entry codes c Prior to operation of a second door relay 2 must be set for...

Page 12: ...ing codes remove a single code or remove all codes Remove an user code Enter To add an entry code Enter Enter the 2 digit index number max 50 Enter Select door and mode of entry required for this entry code Enter 4 5 or 6 to correspond to no of digits in code Enter or or Enter new code Remove all user codes Enter Enter Enter Index number where code is to be removed Enter Door 1 Timed Enter Door 1 ...

Page 13: ...n seconds 01 98 Listen for the accept beep NOTE If the strike time is required to be set to zero secs then you must enter 99 An entry of 00 will give you a strike time of 1 second ii Setting the Door 2 Strike Time To set the Door 2 strike time log on then enter 6 to select the Door 2 Strike Time Set Up function Listen for the accept bleep Then enter a two digit number to set the duration of the st...

Page 14: ...ed to deter any attempt to gain unauthorised access by guessing the format of a valid code To set the Invalid Code Penalty Time log on to Programming Mode then enter 7 to select the Invalid Code Penalty Time function Listen for the accept bleep Then enter a two digit number to set the duration of the Penalty Time in seconds 01 99 Listen for the accept bleep Enter 0 to Log Off Listen for the accept...

Page 15: ...n be re closed or a forced door can be closed then keying in a valid Entry Code will silence and reset the alarm If for any reason the cause of the alarm can not be rectified e g The keypad has been forced away from the wall or the door has been damaged and can not be closed then the alarm can be silenced by keying in a valid Entry Code twice 2 times When the alarms have been silenced in this way ...

Page 16: ...nected between terminals 9 and 1 0V Return and the Door Sensor This disables the door forced alarm feature To utilise the door sensor remove the hard wire bridge and connect the door sensor to terminals 1 and 9 Activating the Operator Under Duress Alarm The Operator Under Duress Alarm can be activated at any time by prefixing a valid entry code with the numbers 9 1 Note if there is any possibility...

Page 17: ...ise 8 The door opens for too long 9 What are the door release relays rated at 1 The door is locked when it should be open and open when it should be locked Check the type of lock that is installed Does it require power to open it or power to lock it This will determine which keypad terminals should be connected If the lock requires power to open it then the lock should be connected to zero volts a...

Page 18: ...o 99 seconds can be programmed If the above situation is suspected the following routine should be carried out 1 Check that all connections to the keypad power supply and locking device are still secure Ensure that the suppresser Metal Oxide Varistor MOV is connected across the lock terminals Ideally this should be located as close to the lock as possible 2 Reset a workable strike time as follows ...

Page 19: ...nd fit a separate bell push button The bell connection terminal No 8 is an open collector gate The bell should be connected to the Strikemaster keypad via a relay The coil on the relay should be connected to the positive supply connection terminal No 2 and the bell connection terminal No 8 When the bell key is pressed a transistor linked to terminal 8 will be driven low This will allow current fro...

Page 20: ...ts will cause relay 1 connections to change to open circuit this could be used to switch off the alarms The second 4 digits will then open the door Please note This configuration may not be suited for applications where the driver may have to enter the door on more that one occasion This is because the alarms will toggle on and off each time the 8 digit entry code is pressed so there is a danger t...

Page 21: ...ove all user codes Enter Enter Enter Index number where code is to be removed Enter Door 1 Timed Enter Door 1 Latched Enter Door 2 Timed Enter Door 2 Latched Enter Index allocated delete fields Index allocated try another Index No Door 1 Enter To set door strike times Door 2 Enter Enter Strike Time in seconds Enter To reset Invalid Penalty Time Enter Enter Penalty Time in seconds Enter Alarm Enter...

Page 22: ...ngineering Manual AXS Strikemaster Programming and Operation Manual May 2013 Page 22 of 22 For more information visit www storm interface com Copyright Storm Interface 2013 All rights reserved Programming Quick Reference ...

Reviews: