Order number: 900350.011
V2.70
Seite 22
11
12
13
14
15
Status 3 (S-3): internal signals
0
Warning message „Oil“, without blocking
1
Warning message „Oil“,without blocking
2
Warning message „Oil“ acknowledged
3
Acknowledgement for "Oil" enabled (cold fat)
4
Warning „FAt“
5
LowFat- or NoContact mode is checking
6
LowFat mode active (only once after switching on)
7
NoContact mode active (only once after switching on)
8
Feedback signal given to input E2 (switching direction taken into account)
9
Burner start phase
10
burner start-up phase
11
Burner restart
12
Burner error
13
Burner is switched on
14
Burner clocking under setpoint value active
15
Burner clocking was active
D. MainFlags (corresponds Status64 Index 3)
Description
Bit
Function
Message
MainFlags[0]
0
Panel On
1
Timer running!
2
Buzzer on because end of baking
3
Intern: button beep
4
Intern: buzzer on for alarm
5
Intern: buzzer on for error
6
Intern: buzzer acknowledged
7
Intern: Parameterization (via buttons) active
8
Intern: Display Temperatures
9
Setpoint display
10
Time adjustment active
11
Heating cycles active
12
Heating cycles ready
13
“Superturbo” free, i. e. can be activated
14
„Superturbo” activated
15
Hot fat, registration is released
MainFlags[1]
0
Warning message “Oil”, without blocking
1
Warning message “Oil”, without blocking
2
Warning message “Oil” acknowledged
3
Acknowledgement for "Oil" enabled (cold fat)
4
Warning „FAt“