Order number: 900350.011
V2.70
Seite 18
Error and warning messages
Display
Cause
Remedy
E1
Sensor error
(Heating relay and analogue output are switched
off!)
Check sensor
Ptc
Sensor error on compensation element for
thermocouple measurement (P91=1,2)
Repair of controller
UEb
Overtemperature at E2 (P35=0, P52=1)
-----
Hot
Overtemperature at E2 (P35=1, P52=1)
-----
FAt
Alarm of the LowFat or NoContact control
settings
Check oil level and/or switch on/off
by pressing OFF button
EP
Error in parameter memory
Repair of controller
OIL
control active
Warning message, fat operating time is
exceeded (see P82)
Acknowledge with the temperature
DOWN key
OIL
control blocked
Control is blocked,, fat operating time is
exceeded (see P82)
Acknowledge with the MELT and
START key
rES
Reset of fat operating time (see P86)
-----
Display flashing
Threshold alarm (P25=1)
-----
Timer lamp
flashing
Timer has elapsed (see P27 and P29)
Acknowledge with the DOWN key
Lamp "HEAT"
flashing slowly
Burner fault (see P58)
Switch on/off by pressing OFF
button
Lamp "HEAT"
flashing quickly
Burner restart chance (see P58)
Switch on/off by pressing OFF
button
„- - -“ flashing
during setup
Button lock (P19=1)
-----