Order number: 900350.011
V2.70
Seite 9
Para-
meter
Description of function
Setting range
Default
value
Cust.
value
P74
Activation of burner clocking
0: Not active
1: Burner clocking below setpoint
1
P75
Duration of basket lowering at K3 at
start of timer
0...30 sec.
(0 sec. = inactive)
5 sec.
P76
Duration of basket raising at K4 at start
of timer
0...30 sec.
(0 sec. = inactive)
5 sec.
P77
Selection of post-frying time
0: Fixed time
1...20: Elastic time
0
P78
Activation of heating clocking
0: Not active, always turbo heating
1: Gentle heating
1
P79
Threshold for return to
heating clocking mode
0.0...99.0 °C
50.0 °C
Operating time parameters
P81
Temperature limit for
fat operating time elapsed
0.0...999 °C
999 °C
P82
Fat operating time until
warning message
0...99 hrs.
(0 hrs. = inactive)
0 hrs.
P83
Fat operating time until
controller block
0...99 hrs.
(0 hrs. = inactive)
0 hrs.
P84
Display of fat operating time
-----
-----
P85
Temperature limit for reset of fat
operating time
(only effective if P86 = 2)
-99...999 °C
100 °C
P86
Reset option of fat operating time
0: No restrictions
1: After warning message or blocking
2: After warning message or
blocking plus cool-down
2
Sensor and hardware parameters (if changed, Mains Off required)
P91
Selection of sensor type
0: Pt100 2-wire
1: Thermocouple type J (Fe-CuNi)
2: Thermocouple type K (NiCr-Ni)
0
P92
Display compensation
-----
-----
P93
Software filter depth
1...64
8
P94
Mains frequency
0: 50 Hz
1: 60 Hz
0
P95
Type of analogue output
0: 0-10 V
1: 4-20 mA
1
LowFat- and NoContact settings
H1
Temperature increase for test heating
„LowFat“
0.1…99.0 K
1.0 K
H2
Minimum duration for test heating
„LowFat“
0…240 sec.
(0 sec. = inactive)
0 sec.
H3
Maximum duration for test heating
„NoContact“
0…240 sec.
(0 sec. = inactive)
0 sec.
H4
Temperature increase for test heating
„NoContact“
0.1…99.0 K
1.0 K
H5
Maximum temperature for
LowFat- and NoContact settings
1…990 °C
60 °C