Order number: 900350.011
V2.70
Seite 6
Parameter table
1. Setpoint level
Parameter Description of function
Setting range
Default
value
Customer
value
Reference temperatures
S1
Temperature setpoint 1:
P4...P5
110 °C
S2
Temperature setpoint 2:
P4…P5
120 °C
S3
Temperature setpoint 3:
P4...P5
130 °C
S4
Temperature setpoint 4:
P4...P5
140 °C
S5
Temperature setpoint 5:
P4...P5
150 °C
Timer values
T1
Time 1:
0:00 to 59:59 min.
1:11 min.
T2
Time 2:
0:00 to 59:59 min.
2:12 min.
T3
Time 3:
0:00 to 59:59 min.
3:13 min.
T4
Time 4:
0:00 to 59:59 min.
4:14 min.
T5
Time 5:
0:00 to 59:59 min.
5:15 min.
2. Parameter level
Para-
meter
Description of function
Setting range
Default
value
Cust.
value
General control parameters
P1
Delta W control circuit 2
-99...+99.0 K
10.0 K
P2
Hysteresis control circuit 1
0,1...99.0 K
1.0 K
P3
Hysteresis control circuit 2
0,1...99.0 K
1.0 K
P4
Bottom setpoint limitation
0...999 °C
0 °C
P5
Top setpoint limitation
0...999 °C
999 °C
P6
Correction actual value 1
-20.0...+20.0 K
0.0 K
P7
Display actual value 1
-----
-----
P8
Initial temperature selection
after Mains On
0: Selection as before
1...5: Selection of setpoint 1...5
0
P9
Initial time selection after Mains On
0: Selection as before
1...5: Selection of time value 1...5
0
Pid parameter
P11
Control circuit 1: Proportional range in
PID control
0.1…999 K
20.0 K
P12
Control circuit 1: Integral time in PID
control (I portion)
0...999 sec.
(0 sec. = inactive)
500 sec.
P13
Control c. 1: Derivative action time in
PID control (D portion)
0...999 sec.
(0 sec. = inactive)
50 sec.
P14
Control circuit 1:
Cycle time in PID control
2...100 sec.
10 sec.
P17
Behaviour of the MELT/TURBO LED
0: on during MELT
1: on during TURBO
0
Relay delay
P18
Switch-off delay for heating relay
0.0...99.0 sec.
0.0 sec.