Parameter tables
Basket control
The Basket control for automatic basket handling is also configured in this level.
It consists of 2 independent modules, which are configured through
o70
...
o73
and
o75
...
o78
.
Para-
meter
Functional description
Setting range
J1=0
J1=1
o10
OIL CHECK configuration
0: No oil check
1: Oil check with 1 sensor (
o20
> 0,
o30
= 0)
2: Oil check with 2 sensors (
o20
> 0,
o30
> 0)
0
o20
OIL CHECK - oil sensor
0: Disabled
1: F1
2: F2
3: F3
4: F4
5: F5
6: F6
7: Virtual Sensor VF1
8: Virtual Sensor VF2
9: Virtual Sensor VF3
10: Virtual Sensor VF4
1
o21
OIL CHECK fast time
0…999s
10
o22
OIL CHECK max temperature increase during fast time
0.1…999.9 K
10
o23
OIL CHECK slow time
0…999 sec
60
o24
OIL CHECK min temperature increase by the end of the
slow time
0.1...999.9 K
10
o25
OIL CHECK temperature limit
0.1…999 °C
40.0
o26
OIL CHECK number of attempts
1 ... 20
4
o27
OIL CHECK Auto. retry
0: always prompt
1: prompt after 1st attempt, auto afterwards
2: always auto retry
0
o28
OIL CHECK dtMAX heat up
0.0 ... 999.0 K
20.0
o29
OIL CHECK dtMAX normal operation
0.0 ... 999.0 K
45.0
o30
OIL CHECK pan sensor
see
o20
0
o31
OIL CHECK auto delay time
1 ... 999 sec
60
o40
OIL QUALITY sensor
0: Disabled
1: ...
1
o41
Limit OIL QUALITY Warning 1
0…100.0 %
50.0
o42
Limit OIL QUALITY Warning 2
0…100.0 %
50.0
Oil counter settings
o51
Temperature limit oil-timer
0.0…999.9°C
999.9
o52
Oil timer warning
0…999 h
20
o53
Oil timer lock
0…999 h
25
o54
Display oil timer hours (Add
o55
for the full timer)
- h
0
o55
Display oil timer seconds (Add
o54
for the full timer)
- sec
0
Oil filtration settings
o61
Minimum temperature value oil filtration
-199.9 …
o62
°C
120.0
o62
Maximum temperature value oil filtration
o61
… 999.9 °C
170.0