Order number: 900318.002 V0.31
Page 14
© Störk-Tronic 2021 • www.stoerk-tronic.com • Subject to modifications.
Parameter tables
Para-
meter
Functional description
Setting range
J1=0
J1=1
C54
Selected Special process
1: Superturbo
(2-point-control instead of PID)
2: Blanching
3: Filtration (see
o63
)
4: measure oil quality
1
C55
Max duration SUPERTURBO
0…300 min
45
C56
Cancel temperature offset SUPERTURBO
0.0 ... 20.0 K
15.0
C60
Setpoint blanching
0.1…999°
150.0
C61
Duration blanching
0 ... 9000 sec
600
C62
Max power at end of blanching
0.0 ... 100.0%
50.0
C63
Duration reduced power at end of blanching
0 ... 900 sec
45
C80
Setpoint ECO
-999…999°
130.0
C81
Duration ECO
0….600 Min
120
C85
Pre-Heat, Melt enabling
The power is set through the on- and off times. If available, the Fryer will
output analog outputs of corresponding power, reducing stress on the
device.
0: both disabled
+1: MELT
+2: Pre-Heat
3
C87
Upper limit Melt STOP
C90
... 100.0 °C
70.0
C88
On time MELT
0 ... 999 sec
60
C89
Off time MELT
0 ... 999 sec
60
C90
Return to melt cooldown temperature
0.0 ... 999.0°C
60.0
C91
Upper limit Pre-Heat STOP
-999.0 ... 0.0K
-15.0
C92
On time Pre-heat
0..999 sec
45
C93
Off time Pre-heat
0 ... 999 sec
60
C96
Energy controller on time
0 ... 999 (unit
C98
)
10
C97
Energy controller off time
0 ... 999 (unit
C98
)
20
C98
Energy regulator period unit
1: 100 ms
2: 1 sec
3: 1 min
4: 1 hour
2
C99
Password
-99 ... 999
0