Key 5+6: Reset operating time recording
By a simultaneous pressing of these keys a reset of the time recording is caused, the
display indicates “rES”. After releasing the keys the alarm message "OIL" is deleted and
if necessary the regulation blocking is cancelled. The accumulated operating time is
deleted.
Note that a reset is only possible in case of an alarm message or blocking and below
the adjusted temperature limit value. This is to prevent the user from operating the
deep-fryers without replacing the fat. However an unconditional reset can be enabled
by means of parameters.