Para-
meter
Function description
Adjustment range
Standard
setting
Custom
setting
A31
Special function at
boundary alarm
0: no special function
1: flashing display
2: buzzer
3: flashing display and buzzer
4: like 3, buzzer can be cancelled
4
A32
Setpoint display
0: display shows actual value
1: display shows setpoint S1 (S1‘)
0
A33
Switching input E1 (if
available)
0: not active
1: timer start possible
0
A34
Switching input E2 (if
available)
0: not active
1: setpoint reduction possible
(S1' relative to S1)
0
A40
Hysteresis mode contact
K1
0: symmetrically
1: one-sided
1
A41
Hysteresis mode contact
K2
0: symmetrically
1: one-sided
1
A51
Minimum action time
contact K1 „Off“
0.0...99.0 sec.
0.0 sec.
A56
Alarm suppression after
“mains on” / ”standby-on”
0…60 min.
0 min.
A60
Sensor type
11: Pt100 2-wire
21: PTC
22: Pt1000 2-wire.
11
A70
Software filter
1: not active, or else
2…32: average value with 2…32
measuring values
2
A80
Temperature scale
0: Fahrenheit (“AUS”)
1: Celsius (“AUS”)
2: Fahrenheit (“OFF”)
3: Celsius (“OFF”)
3
A85
Reset mode of fat operation
time
0: reset after alarm message or
blocking and cool down
1: reset unconditionally
1
A86
Key delay for standby-key
0...100 (x 0.1 sec.)
10
(=1 sec.)
A87
Standby-function with key
On/Off
0: no function
1: standby function
1
A88
Reduced heating
0: not active, Turbo heating
1: active
1
A89
Initial setpoint selection
after mains on and/or
standby
0: same as before
1: S1
2: S2
3: S3
3
A90
Output connection relay K1 0: no connection
1: connection to contact K1
2: connection to contact K2
3: connection to alarm contact
1