A40: Hysteresis mode contact K1 
A41: Hysteresis mode contact K2 

These parameters allow selection as to whether the hysteresis values which are adjustable with 
P2, P3  are set symmetrically or one-sided at the respective switching point. At symmetrical 
hysteresis, half of the hysteresis’ value is effective below and half of the value above the switching 
point. The one-sided hysteresis works downward with heating contact and upward with cooling 
contact (see fig. 1 + 2).  

 
A51: Minimum action time K1 “off” 

These parameters permit a delay in switching on the relay in order to reduce the switching 
frequency. The adjusted time sets the entire minimum time period for a switching-off 
phase. 

 
A56: Alarm suppression after ”mains-On” and/or "Standby-On" 

This parameter allows a switching-on delay of the alarm contact after switching on the mains 
voltage or standby. This delay corresponds with the time set here. 

 
A60: Sensor type 

These parameter permits selection of the sensor type, if the needed hardware prerequisites are 
available. 
 

 
A70: Software filter 

With several measuring values, it is possible to obtain an average value. This parameter can 
determine by how many measured values an average value is to be formed. If a sensor with a very 
fast reaction to external influences is used, an average value ensures a calm signal course. 
 

A80: Temperature scale 

Indication can be switched between Fahrenheit and Celsius. At conversion, the parameters and 
setpoints maintain their numerical value and adjustment range. (Example: A controller with the 
desired value of 0°C is switched to Fahrenheit. The new desired value is then interpreted as 0°F, 
which corresponds to a temperature of -18°C). 
NOTE: Indication limits with °F can be smaller than the actual measuring range! 

 
A85: Reset mode of fat operation time 

To force the exchange of used fat, a reset of the fat operation time is only possible in case of an 
alarm message or regulation blocking together with the cool-off according to parameter P29. 
If the fat exchange is secured otherwise an unconditional reset can be enabled with this parameter. 
  

A86: Key delay for Standby key 

This parameter is to activate a delay time for the On/Off key. Please note the 0.1 seconds scale. 

 
A87: Standby function with Start/Stop key 

The standby function can be disabled. 
 

A88: Reduced heating 

With this parameter the “reduced heating” mode can be enabled. 
 

A89: Initial setpoint selection after mains on and/or standby  
 

Summary of Contents for 900219.092

Page 1: ...ller and is cut to the use with deep fryers It has a 4 digit LED display 6 keys 2 relays and a switching input The different temperature setpoints and timer defaults can be parametered directly by the keys Sensor multi resistance input Range dependent on the type of sensor Front size 106mm x 68mm Panel cut out 87 5mm x 56 5mm Tightness front IP64 Connector screw terminal ...

Page 2: ......

Page 3: ...ivated with parameters The output relays are two change over contacts The functions heating control contact 2 or alarm can be assigned to each output even the deactivation of a output is possible The controller has the possibility of a particularly careful heating in case the deep fryer fat is not yet melted This retarded heating process Melt function is always activated after switching no the uni...

Page 4: ...ing time is shown only for a moment but the flashing LED indicates the elapsing timer A permanent display of the remaining time can be activated with parameters then the LED of the timer is permanently on If the key is pressed for 5 seconds the timer is stopped and the display indicated 0 00 Key 3 4 setpoint reduction Simultaneously pressing these two keys activates the setpoint reduction in addit...

Page 5: ...e OIL is deleted and if necessary the regulation blocking is cancelled The accumulated operating time is deleted Note that a reset is only possible in case of an alarm message or blocking and below the adjusted temperature limit value This is to prevent the user from operating the deep fryers without replacing the fat However an unconditional reset can be enabled by means of parameters ...

Page 6: ...ing PID Turbo was possible the key now is ineffective 3 A6 1 A88 0 The melt function is deactivated and the PID control activated The controller has no reduced heating phase below the limit P37 In each case where switching Melt Turbo was possible it is now possible to switch between PID Turbo 4 A6 0 A88 0 Both the melt function and the PID control are deactivated The controller has no reduced heat...

Page 7: ...ndicated by pressing keys 3 4 together By additionally pressing the UP or DOWN key it can be adjusted Para meter Function description Adjustment range Standard setting Custom setting S1 S2 S3 Temperature setpoints the currently selected setpoint is indicated and or adjusted P4 P5 C 170 C 160 C 100 C T1 Timer setpoint 0 00 99 99 Min 1 11 Min S1 Setpoint reduction is added to the main setpoint in ca...

Page 8: ...0 C P5 Control range limitation maximum setpoint P4 999 9 C 205 C P7 Proportional band 1 100 K 10 0 K P8 Reset time Tn I factor 0 999 sec 0 sec inactive 0 sec P9 Lead time Tv D factor 0 999 sec 0 sec inactive 0 sec P10 Cycle time Tp 2 100 sec 10 sec P19 Key lock only for setpoint setting 0 no key lock 1 key lock 0 P20 Indication of actual value sensor F1 P21 Actual value correction sensor F1 20 20...

Page 9: ... 2 Cooling controller symmetrical hysteresis The hysteresis is only effective if thermostatic mode is enabled in case of PID characteristic it is ineffective P4 Control range limitation minimum setpoint P5 Control range limitation maximum setpoint The adjustment range of the setpoint can be limited in both directions This is to prevent the end user of a unit from setting inadmissible or dangerous ...

Page 10: ...ure limit for fat operating time Above this temperature the internal recording of fat operating time is started If the values of P26 and P27 are exceeded the alarm message and or regulation blocking is activated P26 Fat operating time until fat alarm message After this time period an alarm message requests the exchange of the deep frying fat The display indicates flashing OIL With P26 0 this funct...

Page 11: ... boundary value Fig 5 Boundary alarm rel boundaries Range alarm function see fig 6 Opposite switching behaviour to the boundary value alarm The alarm contact is closed if the actual value remains between the boundary values Fig 6 Range alarm abs boundaries P32 Hysteresis alarm contact The hysteresis can be set symmetrically or one sided at the adjusted limit values see A42 It becomes effective dep...

Page 12: ...1 cooling contact 0 A2 Switch mode contact K2 0 heating contact 1 cooling contact 0 A3 Function of contact K1 at sensor error 0 relay off 1 relay on 0 A4 Function of contact K2 at sensor error 0 relay off 1 relay on 0 A5 Selection setpoint 2 or DeltaW 0 operation with setpoint 2 1 operation with DeltaW 0 A6 Control characteristics contact K1 0 thermostatic 1 PID 0 A8 Display mode 0 integrals 1 res...

Page 13: ...ff 0 0 99 0 sec 0 0 sec A56 Alarm suppression after mains on standby on 0 60 min 0 min A60 Sensor type 11 Pt100 2 wire 21 PTC 22 Pt1000 2 wire 11 A70 Software filter 1 not active or else 2 32 average value with 2 32 measuring values 2 A80 Temperature scale 0 Fahrenheit AUS 1 Celsius AUS 2 Fahrenheit OFF 3 Celsius OFF 3 A85 Reset mode of fat operation time 0 reset after alarm message or blocking an...

Page 14: ...ontact K1 at sensor error A4 Function of contact K2 at sensor error At sensor error the selected relay falls back into the condition pre set here If there is a data loss in parameter memory display indicates EP both contacts K1 and K2 are switched off A5 Selection setpoint 2 or DeltaW This parameter determines whether the setpoints for thermostat 1 and 2 independently adjustable A5 0 or whether th...

Page 15: ...e temperature lies beyond them In the case of sensor error the alarm is activated independently of this adjustment The output can be inverted to operate as a release A31 Special function at boundary or alarm Here can be selected whether in the case of an alarm the indication to flash and or the buzzer is to start Sensor alarm display F1L or F1H is indicated independently thereof by flashing displa...

Page 16: ... This parameter can determine by how many measured values an average value is to be formed If a sensor with a very fast reaction to external influences is used an average value ensures a calm signal course A80 Temperature scale Indication can be switched between Fahrenheit and Celsius At conversion the parameters and setpoints maintain their numerical value and adjustment range Example A controlle...

Page 17: ...eliminated by resetting the unit the controller must be repaired OIL flashing regulation runs Alarm message caused by fat operation time exceeding see P26 Delete with DWON key OIL flashing regulation blocked Regulation blocking caused by fat operation time exceeding see P27 Delete with MELT ON OFF key rES Confirmation of the reset of the fat operating time Key lock see P19 and or A19 Flashing disp...

Page 18: ...r PTC Pt100 Measuring range PTC KTY81 121 50 C 130 C Pt100 80 C 400 C Accuracy 0 5K 0 5 at 25 C without sensor 1K 0 5 of scale range 0 55 C without sensor Outputs K1 Relay 10 1 5 A 250V change over contact K2 Relay 8 1 5 A 250V change over contact Summer ca 85dB Display One 4 digit LED Display height 13 mm colour red 6 LEDs for status display Power supply 230 V 50 60 Hz power consumption max 6 VA ...