Connection
Commissioning Instructions I/O Terminal Module
29
ID 441758.05
WE KEEP THINGS MOVING
4
4.3
X141: Motor temperature sensor
Prerequisite for using interface X141:
•
REA 5001
Terminal description – X141
MDS 5000
Example of connection of X141 and X2
Example of connection of X141 and X2
Pin
Function
Description
1
1TP1/1K1 +
Thermal motor protection signal, comes from X140 pin 7
2
1TP2/1K2 -
Thermal motor protection signal, comes from X140 pin 14
maximum conductor cross-section
Connection type
maximum conductor cross-section
[mm
2
]
rigid
1,5
flexible
1,5
Flexible with cable end, without plastic
sleeve
1,5
Flexible with cable end, with plastic
sleeve
0,75
2 leads with the same cross-section
with double cable end
—
3
1
4
2
X2
X141
REA 5000/REA 5001
Inverter
of X140 Pin 7
of X140 Pin 14
1
1
2
2
X2
X141
REA 5000/REA 5001
SDS 5000
of X140 Pin 7
of X140 Pin 14