Do not allow refrigerants to contact open flame. Decomposition will occur.
Inhalation of decomposition is harmful.
x
First Aid:
Inhalation:
If high concentrations of refrigerant vapors are inhaled,
immediately remove the person(s) to fresh air. Keep calm.
If not breathing, give artificial respiration. If breathing is
difficult, give oxygen. Call a doctor. Do not give
epinephrine or similar drugs.
Eye Contact: In case of liquid contact, immediately flush eye with water.
Seek medical attention.
Skin Contact: Flush with water. Treat for frostbite by gently warming the
affected area.
x
Know your equipment:
Read and understand the User Manual and
labels affixed to the unit. Learn the application and limitations as well as
the specific potential hazards of your equipment.
x
Ground all equipment:
Stinger is equipped with a three-pronged
grounded power cord.
x
Use the proper extension cord:
Keep extension cord length to a
minimum. Use the following guide for choosing the proper extension cord:
18 gauge cord – maximum length 10 feet
16 gauge cord – maximum length 25 feet
14 gauge cord – maximum length 50 feet
12 gauge cord – maximum length 100 feet
x
Use approved hoses:
Use refrigerant connection hoses that are
approved to SAE J2196-1992. These hoses must provide a shut-off device
within 12 inches of the ends, and must be approved for outdoor usage.
x
Use approved recovery tank:
Use a DOT approved refrigerant recovery
tank made for use with the type of refrigerant being recovered. Note that
R-410 is capable of pressures exceeding 600 psi. Typical DOT recovery
cylinders are rated at 350 psi with a pressure relief set at 550 psi. These
cylinders should not be used with R-410A. Only cylinders rated at 400 psi
with the relief valve setting at 600 psi should be used to for R-410A.
Failure to use the proper cylinder can be extremely dangerous!
Summary of Contents for Refrigerant Recovery Unit
Page 9: ...2090 0217 Rev 6 9 Descriptions of Features Figure 1 Stinger Front View...
Page 15: ...2090 0217 Rev 6 15 Figure 3 Standard Recovery Hose Connections...
Page 18: ...18 2090 0217 Rev 6 Figure 4 Liquid Push Pull Recovery Operation...
Page 21: ...2090 0217 Rev 6 21 Figure 6 Special Notes for R410 A Recovery...
Page 26: ...26 2090 0217 Rev 6 Figure 8 Recovery Tips...
Page 30: ...30 2090 0217 Rev 6 Schematic Diagram Figure 9 Schematic Diagram...
Page 32: ...32 2090 0217 Rev 6 Figure 10 Stinger Exploded View...
Page 34: ...34 2090 0217 Rev 6 Figure 11 Compressor Exploded View...