PROBLEM
CAUSE
ACTION
Recovery process
too slow
Head pressure too high
System refrigerant iced up
Restriction in hoses or
manifold gauge set
Compressor seals worn
Reduce tank temperature or
change tanks.
Throttle gauge manifold
valves and discharge valves
to reduce pressure
differential between LP and
HP gauges.
Interrupt recovery process
and allow ice to dissipate.
Check and clear restriction.
Rebuild compressor.