8
2090-0217 Rev 6
Specification
Description
Compatible
Refrigerants
R-12, R-22, R-114, R-134a,
R-401A,
R-401B, R-401C, R-402A, R-402B, R-404A,
R-406A, R-407A, R-407B, R-407C, R-407D,
R-408A, R-409A, R-410A, R-411A, R-411B,
R-412A,
R-500, R-502, R-507, R-509
Power
1 Phase, 50/60 Hz, 8 A
1 Phase, 50/60 Hz, 5 or 10 A
1 Phase, 50/60 Hz, 5 A
(See
label on
back of
unit)
Compressor
¾ HP High Performance Oilless
Cooling Two
Cooling
Fans
Protection
High pressure cutoff at 550 psi. Compressor is protected by
circuit breakers and internal compressor thermal sensor.
Optional 80% tank full shutoff kit (P/N 2090-0091).
Pressure
Ratings
Low Side design pressure 450 PSI
High Side design pressure 550 PSI
Temperature
Operating Range 32 to 104
q
F (0 to 40
q
C)
Case Blow-Molded,
High
Impact
Polyethylene
Size (LxWxH)
17" x 9.5" x 11"
(43.2 cm x 24.1 cm x 27.9 cm)
Weight 28
Lbs
(12.7
kg)
Certification
Complies with UL1963 (not evaluated for automotive use)
Summary of Contents for Refrigerant Recovery Unit
Page 9: ...2090 0217 Rev 6 9 Descriptions of Features Figure 1 Stinger Front View...
Page 15: ...2090 0217 Rev 6 15 Figure 3 Standard Recovery Hose Connections...
Page 18: ...18 2090 0217 Rev 6 Figure 4 Liquid Push Pull Recovery Operation...
Page 21: ...2090 0217 Rev 6 21 Figure 6 Special Notes for R410 A Recovery...
Page 26: ...26 2090 0217 Rev 6 Figure 8 Recovery Tips...
Page 30: ...30 2090 0217 Rev 6 Schematic Diagram Figure 9 Schematic Diagram...
Page 32: ...32 2090 0217 Rev 6 Figure 10 Stinger Exploded View...
Page 34: ...34 2090 0217 Rev 6 Figure 11 Compressor Exploded View...