22
TEMPERATURE OVERVIEW
An overview of the temperature control or growth
curve selected is shown.
Animal weights equal to or greater than 10,000
grams are displayed in kilograms. I.e. 10,000
(grams) is shown as 10.0 (kg).
Use the
or
key to select the next/previous
control, overview or sensor.
You can use “Clear running hours” in screen 172
(overview of heaters) to clear the operating hours
of all heaters in one action.
You can use the “Reset min/max temp.” setting to clear the min/max measurements in all temperature listings
and to fill “Today” with the current value.
ALARM
House temperature limits
The temperature limits apply to
all
ventilation groups.
Outside temperature compensation on behalf of alarm
The following applies to all controls: if the outside
temperature rises to above the temperature that has been
set, the maximum temperature alarm limit will be corrected
upwards until the absolute alarm limit is reached. This
compensation prevents the alarm from being activated
unnecessarily when outside temperatures are high.
However, the corrected alarm limit can never be higher
than the absolute temperature limit setting. An alarm is
generated if the current temperature rises to above the
absolute value.
The absolute alarm limit warns you that the temperature in
the house has become far too high and that you may have
to take additional measures to lower the temperature in the
house.
22°C
25°C
35°C
29°C
35°C
32°C
OUTSIDE TEMPERATURE
ABSOLUTE UPPER LIMIT
CORR
EC
TED
MAX
IMUM
TE
MPE
RATURE ALA
R
M LI
MI
T