INSTALLATION
Maintenance
26
|WPL ICS classic | WPL IKCS classic
www.stiebel-eltron.com
f
f
Pull the EPS cover 6 to 8 cm to the right.
f
f
Tilt the top of the EPS cover towards you from the appliance.
f
f
Pull the EPS cover upwards to remove.
26
0
4
01
0
57
5
f
f
Remove the dirt grille fitted above the condensate pan by
compressing it from its sides and removing it upwards.
f
f
Check the defrost pan drain and clean it, if required.
Below the evaporator is a two-part evaporator gasket. The two
parts of the gasket are connected with a bracket.
26
0
4
01
0
57
7
f
f
Pull the bracket upwards to remove.
f
f
First remove the l.h. half of the evaporator cover.
26
0
4
01
0
59
1
f
f
Then remove the r.h. half of the evaporator cover.
!
Material losses
When cleaning the evaporator fins, ensure that no water
comes into contact with the PCB.
!
Material losses
Do not use any cleaning agents, just water.
!
Material losses
Do not use a high pressure cleaner otherwise the evap-
orator fins may be bent.
f
f
Spray water across the evaporator fins.
f
f
Remove the water from the appliance using a wet suction
device.
f
f
Remove contaminants and blockages.
Note
Check the condensate drain regularly, at least once a year.
18.2 Cleaning the condensate drain
Check the condensate drain regularly.
f
f
Remove the evaporator cover (see chapter "Cleaning the
evaporator fins").
f
f
Remove contaminants and blockages.
f
f
To test the drain, pour a litre of water into the condensate
collector.
If the condensate collector does not overflow, the drainage facility
is adequate.