background image

1.1  Description

The 

MEK

MED

, and 

MEB

 single-lever wall fit-

tings are intended for operation of open (non-
pressurised) over-sink water heaters.  
The pivoting outlets (

1

) of the 

MEK

 and 

MEB

 

are equipped with a jet regulator.

1.2  Operation

 

A

When the water is running, the flow rate is 
regulated by pulling on the operating lever (

3

). 

By simultaneously rotating the operating lever, 
the outlet temperature of the water is adjusted 
(hot to the left, cold to the right).

MEB hand-held shower 

C

Switch over between pivoting outlet and 
hand-held shower by pressing the switchover 
element (

8

) while the tap is running. 

Automatic reset to pivoting outlet when the 
tap is turned off.

1.3  Safety instructions

 

As the heater warms up, so the water 
volume increases. In the process, the 

expansion water drips through the outlet of 
the fitting. This is a necessary and normal 
process.

 

Limescale formation can block the 
outlet and so put the heater under 

pressure. Never block off the fitting outlet, 
and do not use any perlators or air bubblers, 
flow limiters, or hoses with jet regulators, 
since otherwise the heater will be damaged.

Shower hoses on the 

MED

 and 

MEB

 fittings 

must not be allowed to become kinked.

1.4  Care and maintenance

A damp cloth is sufficient to clean the water 
heater. Do not use any solvents or abrasive 
cleaning products. 
A jet regulator in the pivoting outlet pipe 
(

1

) which is blocked with limescale must be 

descaled. To do this, remove the jet regulator 
from the screw mounting. 
If necessary, the jet regulator is to be replaced 
with an original Stiebel Eltron jet regulator, 
spare part No. 27 99 32

1.5  Operating and installation in-

structions

 

Keep these instructions in a safe place. 
In the event of a change of owner­

ship, hand them over to the new owner, and, 
in the event of any maintenance or repair 
work, give them to the qualified installer for 
consultation.

1. Operating instructions

 for the user and qualified installer

Installation and connection must be carried 
out by a qualified installer, following these 
installation instructions.

First remove the packing from the fitting 
and accessories at the place of installation, 
making sure the packing enclosures are not 
thrown away. When unpacking, also check 
that no accessories are left behind in the 
packing material.

2.1  Components 

A

 

Pivoting outlet with jet regulator

Hand-held shower with holder

Operating lever

Fitting body

Wall connection socket (SW24) with choke 

valve

30 mm extension

Water inlet pipes – chrome-plated brass

Switchover element, pivoting outlet to 

hand-held shower

2.2  Description of the fitting

The 

MEK

 

MED

, and 

MEB

 single-lever wall 

fittings are intended for operation of open 
(non-pressurised) over-sink water heaters:

MEK 

  Kitchen

MED 

  Shower

MEB 

  Bath/shower

2. Installation instructions

 for the qualified installer

2.3  Regulations and conditions

•  Perfect function and operational reliability 

can only be guaranteed with original Stiebel 
Eltron accessories and spare parts intended 
for the fitting.

•  Any conditions specified by the water supply 

company concerned must be respected.

•  The water heater must not be subjected to 

any water pressure, and the water connec-
tions must not be confused, since otherwise 
the heater will be damaged.

•  A flow pressure of up to 0.6 MPa is permis-

sible. Above 0.6 MPa, a pressure reducing 
valve is to be installed in the main pipe.

 

Non­pressurised water heaters must 
not exceed the following flow rates 

with the valve fully opened: 
5 l/min with a 5 l heater 
10 l/min with a 10 l heater 
12 l/min with => 15 l heater 
If the flow rates are exceeded, the rate is to 
be limited as described under Point 2.4.

•  Flush the cold water inlet pipe through 

thoroughly.

•  If the connecting pipes need to be short-

ened, the pipes are to be internally de-
burred.

2.4  Installation of the fitting 

B

»  Screw the wall connection socket (

5

) into 

the wall disk.

»  Screw the fitting body (

4

) into the wall con-

nection socket 

Note

With heaters from 30 l heater content, the 
30 mm extension (

6

) is to be inserted be-

tween the wall connection socket and the 
fitting body.

» 

D

 Water inlet pipes (

7

) are to be screwed 

in between the water heater and the wall 
fittings.

»  Depending on the fitting, screw the outlet to 

the fitting body. 
With the MEB bath fitting, first screw the 
pivoting outlet to the fitting body, and then 
screw the holder of the hand-held shower 
to the pivoting outlet at the bottom.

Filling the water heater

Pull the operating lever forwards and pivot it 
to the left, wait until the water emerges free of 
bubbles at the outlet, and only then switch the 
heater on.

Setting flow rate

 

C

The flow rate is adjusted by means of the 
choke valve in the wall connection socket (

5

).

»  Remove the cover flap.
»  Using a screwdriver, turn the setting screw 

to the right (lower rate) or to the left (higher 
rate).

Summary of Contents for MEB

Page 1: ...ons Notice D UTILISATION ET DE MONTAGE GEBRUIKS EN MONTAGEAANleiding Armaturen für offene Warmwasserspeicher FITTINGS FOR NON PRESSURISED WATER HEATERS ROBINETTERIES POUR BALLONS D EAU CHAUDE OUVERTS A ECOULEMENT LIBRE KRANEN VOOR OPEN WARMWATERBOILERS MEK MED MEB MEK MED MEB ...

Page 2: ...2 4 Installation of the fitting 3 Fault rectification 9 4 Environment and recycling 9 5 Guarantie 9 Contenu Français page 10 11 1 Notice d emploi 10 1 1 Description 1 2 Utilisation 1 3 Consignes de sécurité 1 4 Entretien et maintenance 1 5 Manuel d utilisation et de montage 2 Manuel de montage 10 2 1 Composants 2 2 Description des robinetteries 2 3 Normes et réglementations 2 4 Montage de la robin...

Page 3: ... 1 2 337 mm 100 70 mm G 1 2 131 mm 100 mm 86 mm 190 mm 103 mm 7 3 4 5 6 G 1 2 337 mm 100 70 mm G 1 2 131 mm 1500 mm 100 mm 86 mm 7 2 3 5 4 6 SW24 5 G 1 2 337 mm 100 mm 100 70 mm 86 mm G 1 2 131 mm 1250 mm 90 mm 119 mm 7 2 3 4 5 1 6 8 MEK MED MEB 8 5 7 ...

Page 4: ...lterung 3 Bedienhebel 4 Armaturenkörper 5 Wandanschlussstutzen SW24 mit Drosselventil 6 Verlängerung 30 mm 7 Wasserzulaufrohre Messing verchromt 8 Umsteller Schwenkauslauf Handbrause 2 2 Armaturenbeschreibung Die Einhebel Wandarmaturen MEK MED und MEB sind zum Betrieb für offene drucklose Übertisch Warmwasserspeicher bestimmt MEK Küche MED Dusche MEB Wanne Dusche 2 3 Vorschriften und Bestimmungen ...

Page 5: ... überprüfen Schlechtes Strahlbild Armatur spritzt beim Zapfen Verkalkung des Strahlreglers Benutzer Fachmann Strahlregler der Armatur reinigen gegebenen falls erneuern Armatur tropft beim Aufheizvorgang Ausdehnungswasser Normaler Vorgang bei drucklosen Speichern Tropfen hört nach Beendi gung des Aufheizvorganges auf 3 Störungsbeseitigung für den Benutzer und Fachmann Deutsch ...

Page 6: ...ft und Abfallgesetzes und der damit verbunde nen Produktverantwortung ermöglicht Stiebel Eltron mit einem kostengünstigen Rücknah mesystem die Entsorgung von Altgeräten Fragen Sie uns oder Ihren Fachhandwerker Fachhändler Die Geräte oder Geräteteile dürfen nicht als unsortierter Siedlungsabfall über den Haus müll bzw die Restmülltonne beseitigt werden Über das Rücknahmesystem werden hohe Recycling...

Page 7: ...ebel Eltron frei eine Reparatur des Gerätes ausführen zu lassen oder selbst auszuführen Etwaige ausgewechselte Teile werden Eigentum von Stiebel Eltron Für die Dauer und Reichweite der Garantie übernimmt Stiebel Eltron sämtliche Material und Montagekosten Soweit der Kunde wegen des Garantiefalles aufgrund gesetzlicher Gewährleistungsan sprüche gegen andere Vertragspartner Leistungen erhalten hat e...

Page 8: ... 1 Pivoting outlet with jet regulator 2 Hand held shower with holder 3 Operating lever 4 Fitting body 5 Wall connection socket SW24 with choke valve 6 30 mm extension 7 Water inlet pipes chrome plated brass 8 Switchover element pivoting outlet to hand held shower 2 2 Description of the fitting The MEK MED and MEB single lever wall fittings are intended for operation of open non pressurised over si...

Page 9: ...rs Dripping will stop when the heating up process has been completed 3 Fault rectification for the user and qualified installer English 4 Environment and recycling Dispose of packing material and appliances The dispose of the packing material and the appliances must be done according to the lo cal recycling laws and regulations For guarantees please refer to the pespective terms and conditions of ...

Page 10: ...ec vanne à bague d étranglement 6 Rallonge 30 mm 7 Tuyau d arrivée d eau Laiton chromé 8 Inverseur bec pivotant douchette à main 2 2 Description des robinetteries Les robinetteries MEK MED et MEB à levier de commande unique sont destinées à l uti lisation de ballons d eau chaude ouverts à écoulement libre montés sur évier MEK Cuisine MED Douche MEB Baignoire douche 2 Manuel de montage à l usage de...

Page 11: ...pérature 3 Résolution de problèmes à l usage de l utilisateur et de l installateur professionnel Français 4 Environment et recyclage La garantie est à faire valoir dans le pays où l appareil a été acheté A cette fin il faut prendre contact avec la filiale Stiebel Eltron concernée à défaut l importateur agréé Le montage les raccordements la maintenance ainsi que la première mise en service sont à r...

Page 12: ... 1 Zwenkuitlaatpijpstuk met straalregelaar 2 Handdouche met houder 3 Bedieningshendel 4 Kraanlichaam 5 Wandaansluitingsstuk SW24 met smoor klep 6 Verlengstuk 30 mm 7 Watertoevoerleidingen messing ver chroomd 8 Schakelregelaar zwenkuitlaatpijpstuk handdouche 2 2 Kraanbeschrijving De éénhendel wandkranen MEK MED en MEB zijn bestemd voor toepassing op open drukloze bovenbouw warmwaterboilers MEK keuk...

Page 13: ...lands 4 Milieun en recycling Aanspraak op garantie bestaat uitsluitend in het land waar het toestel gekocht is U dient zich te wenden tot de vestiging van Stiebel Eltron of de importeur hiervan in het betreffende land De montage de electrische installatie het onderhoud en de eerste inbedrijf name mag uitsluitend worden uitgevoerd door gekwalificeerd personeel De fabrikant is niet aansprakelijk voo...

Page 14: ...3887 Email info stiebel eltron ru www stiebel eltron ru Sweden STIEBEL ELTRON AB Friggagatan 5 SE 641 37 Katrineholm Tel 0150 487900 Fax 0150 48 7901 Email info stiebel eltron se www stiebel eltron se Switzerland STIEBEL ELTRON AG Netzibodenstr 23c CH 4133 Pratteln Tel 061 8169333 Fax 061 8 169344 Email info stiebel eltron ch www stiebel eltron ch Thailand STIEBEL ELTRON Asia Ltd 469 Moo 2 Tambol ...

Reviews: