INSTALLATIoN
Installation alternatives
88
| DHE
www.stiebel-eltron.com
D
00000
56
19
4
1
1 Tab
13.6 Water installation on finished walls with
solder/press fittings
Note
This type of connection changes the IP rating of the ap-
pliance.
f
f
Change the type plate. Cross out "IP 25" and mark
the box "IP 24". Use a ballpoint pen to do this.
You can connect copper or plastic pipes with the accessories "sol-
der fitting" or "press fitting".
With "solder fitting" with threaded fitting for 12 mm copper pipes,
proceed as follows:
f
f
Push the union nuts over the connection pipes.
f
f
Solder the inserts to the copper pipes.
f
f
Push the lower back panel section under the connection
pipes of the tap and push it into the back panel.
f
f
Secure the connection pipes to the tee and the 3-way ball
shut-off valve.
Note
Observe the tap manufacturer's instructions.
13.7 Fitting appliance cover for water installation on
finished walls
D
00000
73
17
0
4
3
2
1
1 Back panel guides
2 Screw
3 Cover guides with sealing lips on the pipe side
4 Pipe knock-out
f
f
Cleanly saw and break out the pipe knock-outs in the appli-
ance cover. If necessary, use a file.
f
f
Click the cover guides into place in the knock-outs.