56
07/13424999918
WPS
®
2 Window Protection System
Description of parameters
Sensor parameter
Delays:
WPS2/A
WPS2/B
About the page frame "Delays" the delay time (value range 0-255 seconds) can be set before releasing the window after
a person is detected in the hazard area. The window will remain locked for the period of time set (
approximately 10
` "] ;Y""Y$
Service Port software. Simply insert a tick next to the sensor signals that are to be delayed.
Test output:
(only for WPS2/A)
If the test output is set to the “Passiv” position, it will constantly produce a signal in the idle state. It will be disconnected
during the sensor test. If the output is set to the “Aktiv” position, the test signal will only be connected for the sensor test.
Test input:
(only for WPS2/A)
The signal polarity can be selected via the test input. In the “Low Aktiv” position, the WPS2 will expect the input to be
closed during the sensor test. In the “High Aktiv” position, the input must be open during the sensor test.
Enabled inputs:
WPS2/A
WPS2/B
X < Y YY ;Y
<[$"]= Y"<< "<
radar sensor, frequency) is removed, the respective sensor is deactivated.
Emergency close:
(only for WPS2/B)
This parameter switches the emergency close input or the emergency close button to active. This enables the drives
connected to close independently from the safety function if voltage is connected to the motor input.
SHE:
(only for WPS2/B)
The “SHE” parameter is used to switch the SHE function on and off. In the ON state, an SHE message will be stored in-
ternally via the SHE input so that the next close command (e.g. “SHE close” on the control panel) can be executed, even
if people are present in the monitored area.
The reactivation of the protective functions of the WPS2 will take place automatically as soon as the motor circuit is
deemed to have completed the closing operation. Closed means that the motor voltage in the closing direction is applied
for the maximum run time (
180 seconds) and the SHE input is not closed.