10

BATTERY REPLACEMENT

Battery replacement instructions – Jupiter 2040 only

When the battery weakens, the red indicator light will blink at a constant rate. 

The battery must be replaced within two weeks.
To replace the battery:

1

Release the screw at the 

bottom of the cover plate and 

remove the cover plate.

2

A. Dis

connect the water pro

of 

     connector between the battery      

     box and the electronic unit.
B. Pull out the battery box 

     from the battery box holder  

     by releasing the bottom clip.
C. Pull out the battery cover.

3

D. Replace the used battery with 

     a new 9V battery (Lithium 

     battery is recommended).
E. Close the battery box and 

     slide it back on the battery      

     holder starting from the 

     bottom upwards.
F.  Connect the connectors.

D

E

F

4

IMPORTANT: Wait a few seconds 

before activating the flush 

valve to avoid entering into 

“adjusting mode”.
Close the battery compartment 

and refit the cover plate.

A

B

C

Summary of Contents for Jupiter 2040

Page 1: ...1 JUPITER 2040 INSTALLATION AND MAINTENANCE GUIDE ELECTRONIC FLUSH VALVE FOR URINALS...

Page 2: ...nce the user moves away from the urinal 1 TECHNICAL DATA 2 PACK CONTENTS 3 PRE INSTALLATION INFO 4 8 INSTALLATION 9 BATTERY REPLACEMENT INSTRUCTIONS SETTINGS ADJUSTMENT 10 11 ADJUSTING THE SETTINGS WI...

Page 3: ...c flush after last use Sensor range 600 mm Factory set Adjustable manually with remote control Flushing Time 6 secs Factory set Adjustable 3 to 20 secs Prior use Flush Mode Optional feature TECHNICAL...

Page 4: ...h valve Familiarize yourself with the part names and confirm that the parts are included 1 x Plastic seat for the cover plate 1 x Wall cover plate with electronic unit battery box included in battery...

Page 5: ...sh valve Familiarize yourself with the part names and confirm that the parts are included 1 x Plastic seat for the cover plate 1 x Wall cover plate with electronic unit battery box included in battery...

Page 6: ...g parts WARNINGS Do not install the system facing a mirror or any other electronic system operated by an infrared sensor To prevent reflection problems it is recommended keep a minimum distance of 1 5...

Page 7: ...for the dimensions of the box and the corrugated tube for E versions not supplied 3 Insert the electronic flush valve box through the opening 4 Connect the flush valve inlet to the water supply 5 Conn...

Page 8: ...o leakage 7 Assemble the mud guard cover to protect the flush valve Note the MIN and MAX marks on the box STEP 2 CONNECTING THE POWER SOURCE 1 Once the electricity plumbing and tile works are finished...

Page 9: ...box inside the box and proceed to clause 4 3 If your model is Jupiter 2040E place the transformer near the electricity plug and insert the transformer cable wire through the box OUTLET 4 Assemble the...

Page 10: ...OURCE 5 Connect the electronic unit connectors to the solenoid valve connector and the power source connector STEP 3 COMPLETING THE INSTALLATION 6 Assemble the panel to the cover seat and lock it with...

Page 11: ...BEFORE ACTIVATING THE FLUSH VALVE TO AVOID ENTERING INTO ADJUSTING MODE 8 Move away and the flush valve will flush a few seconds after your departure 9 If needed adjust the flow capacity by turning th...

Page 12: ...tor between the battery box and the electronic unit B Pull out the battery box from the battery box holder by releasing the bottom clip C Pull out the battery cover 3 D Replace the used battery with a...

Page 13: ...on button a quick flashing of the red light at the front of the sensor will occur At this stage you can change the setting by pressing the or the buttons every push will increase or decrease one level...

Page 14: ...ashing of the red light of the sensor eye is perceived Then press to increase the delay out time and to reduce it 24 HOUR HYGIENE FLUSH If you have a compatible model with a 24 hours hygiene flush it...

Page 15: ...or at a distance of 2 5cm within 5 seconds from the re connection of the power supply Note If you will not put your hand in front of the sensor after connecting the power supply the sensor will not en...

Page 16: ...adjust the flow capacity 7 Make sure that there is no water leakage Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol acid abrasives or the...

Page 17: ...anel Kit Jupiter 2040 2040E 07040214 Panel Kit Jupiter 2040H 2040HE 07040227 10 pack Sensor Kit Jupiter 2040 07220345 8 Pack Solenoid Housing Kit 07221103 Nipple Kit 07246002 Filter 08530013 Switching...

Page 18: ...e of the faucet valve or control If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumbing Contractor Please be sure to provide all pertinent information regardin...

Page 19: ...lashes when user steps within the sensor range Unscrew solenoid pull out the plunger and the spring from solenoid Clean them with pressure or use scale remover material if needed 2 Debris or scale in...

Page 20: ...18 01 16 01500281 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com...

Reviews: